5
Electrical connection
5.1
Connection cable for evaluation electronics
HBM provides the following connector cables for connecting the T20WN,
T21WN and T22 through the VK20 junction box to the evaluation electronics:
S 1-KAB 151A-1.5 (15‐pin D‐sub connector (male) - free ends)
S 1-KAB 152-1.5 (SUBCON5 - free ends)
1-KAB151A-1.5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Fig. 5.1
Cable for connecting to the evaluation electronics
The cable configuration is adjusted to the system device to be connected. In
the junction box housing, there is an instruction leaflet with the connection dia
gram for the various HBM system devices (see both parts of Fig. 5.2).
VK20A
VI
YE
BK
BU
BU/RD
WH
PK
GY/PK
GY
GN
BN
RD
A02335_03_Y00_00 HBM: public
Electrical connection
1-KAB152-1.5
BK
1
BU
2
WH
3
RD
4
GN
5
bared
Shield
9