Screen flashing :
4
« >30A »
+ alarm beep
The GYSFLASH delivers a high cur-
5
rent (greater than 10A) before the
diagnostic tool has been activated.
Displays for 1s :
6
« no battery »
+ alarm beep
The device is locked in Showroom
7
mode
Screen displays :
« #error temp(°C) »
8
+ alarm beep
Screen displays :
9
« #error IHM »
+ alarm beep
Screen displays :
10
« #error fuse »
+ alarm beep
11
The device doesn't display anything
SAFETY
▪ Explosive gas, avoid flame and sparks. During the charge, the battery must be placed in a well ventilated area.
▪ Protect against rain and moisture.
▪ The charger must be connected to an EARTHED power supply.
▪ If the electricity supply cable is damaged, or if the internal fuse has blown (ref 054646), it must be replaced by the manufacturer,
its after sales service, or a qualified person.
▪ Do not use to charge small batteries (i.e those with a capacity less than the minimum stated on the Gysflash), or non rechar-
geable batteries.
▪ Always ensure the Red clamp is connected to the "+" battery terminal first.
▪ If it is necessary to connect the black clamp to the vehicle chassis, make sure it is a safe distance from the battery and the fuel/
exhaust pipe.
▪ After charging, disconnect the charger from the outlet, then disconnect the clamp from the earth and the battery in the indicated
order.
▪ The charger must be positioned so that the socket is always accessible.
▪ This charger is not a toy.
▪This product should be disposed of at an appropriate recycling facility - do not dispose of in domestic waste.
▪ Do not short-circuit the clamps during use.
GYSFLASH 30-12 HF
Consumption exceeds the output of the charger
Several consumers are active on the vehicle
Battery discharged
Showroom mode is working on
« no battery »
Lock Showroom active
Faulty fan
Extended exposure to sunlight
Electronic fault
Mishandling
Input fuse HS
Faulty electrical network
Turn off electrical consumers to reduce power demand
GYSFLASH works to specification. Turn off consumers to check the battery is not
too discharged (see cause n°2).
Battery deeply discharged, the GYSFLASH delivers current to charge it. Wait
until the output current is below 10A to start the diagnostic.
Showroom without battery : GYSFLASH operating normally.
To deactivate the "no battery" function, press the "START/STOP" key, and then
press the "START/STOP" key again to start the Showroom mode with battery.
Normal operation of GYSFLASH.
Refer to configuration menu to deactivate this function.
Contact your distributor.
Do not leave the device exposed to sunlight.
Leave the device ON until the fault disappears. (The alarm beep can be stoppe-
dPossibility to stop the alarm beep by pressing the START/STOP key).
Contact your distributor.
Internal fuse must be changed by a qualified person
(ref. 054646 : 40A).
Input fuse must be changed by a qualified person
(temporised fuse 6.3A 5x20, ref. 054578).
Check the voltage of the electrical network is between 180V and 260V.