ADVANCED MENU
This menu controls the advanced parameters of the charger. To move from one parameter to another push the Select key :
Activation «Power Supply» > Activation «Expert Curve» (> Adjusment of the «Expert Curve» parameters)
SELECT
• POWER SUPPLY mode activation :
To activate the POWER SUPPLY mode, select «ADVANCED MENU | Power
Supply : ON». Now this mode will be accessible from the mode list.
• «EXPERT» curve activation :
To activate the «EXPERT» curve, select «ADVANCED MENU | expert curve
: ON». Now this curve will be available in the charging curves list from the
CHARGE mode.
• Parameters adjustment of the «EXPERT» curve :
If the charging curve «EXPERT» is activated, the charging curve parame-
ters can be adjusted (type IU
- Ucharge: Charge voltage adjustable from 12.0 to 16.0V.
- Urecovery: Recovery voltage adjustable up to 30.0V.
If the value «OFF» is selected the recovery function is inactive.
- Ufloating: floating voltage adjustable depending on the Unominal value
selected.
If the value «OFF» is selected the floating function is inactive.
- Trecovery: Maximum time for cells recovery in short-circuit, adjustable
from 1h to 12h.
- Trefresh: Time for the refreshing phase adjustable from 1h to 12h. If
the value «OFF» is selected, the refresh function is not activated.
aWarning: When charging on vehicle, the refresh function must
not be activated (T refresh: OFF). A voltage «Urecovery» too
high might damage the electronics of the vehicle. We advise NOT
to set-up this setting above 15V.
GYSFLASH 30-12 HF
I
U) :
0
0
ADVANCED MENU
ADVANCED MENU
Power Supply: OFF
ADVANCED MENU
Expert Curve:
OFF
OFF
ON
EXPERT CURVE
Ucharge:
14.3V
EXPERT CURVE
Urecovery:
OFF
EXPERT CURVE
U oating:
OFF
EXPERT CURVE
T recovery*:
5h
EXPERT CURVE
T refresh:
5h
ADVANCED MENU
Save?
No
RETURN
EN
ON
OFF
ON
OFF
12.0V
12.1V
...
16.0V
OFF
Uch
...
29.9V
30.0V
OFF
12.0V
12.1V
...
Uch
1h
2h
...
12h
OFF
1h
2h
...
12h
Yes
No
*accessible only if
Urecovery = OFF