Herunterladen Diese Seite drucken

Belden Hirschmann RSPE Referenzhandbuch Seite 1157

Grafische benutzeroberfläche hios-3s
Vorschau ausblenden Andere Handbücher für Hirschmann RSPE:

Werbung

Industrieprotokolle
17.3 EtherNet/IP
Tab. 73:
Id
Attribute
0x2
Interface Flags
0x3
Physical Address
0x4
Interface Counters Get
0x5
Media Counters
0x6
Interface Control
0x7
Interface type
462
Instanz-Attribute (Forts.)
Access
Rule
Get
Get
Get
Get/Set STRUCT of:
Get
Data type
Description
DWORD
Interface Status Flags:
0:
1:
2:
3:
4:
5:
6:
ARRAY of:
MAC address of physical interface
6 USINT
STRUCT of:
InOctets, InUcastPackets,
InNUcastPackets, InDiscards,
UDINT
InErrors, InUnknownProtos,
MibIICounter1
OutOctets, OutUcastPackets,
UDINT
OutNUcastPackets, OutDiscards,
MibIICounter2
OutErrors
...
STRUCT of:
Alignment Errors, FCS Errors, Single
Collision, Multiple Collision, SQE Test
UDINT
Errors, Deferred Transmissions, Late
EthernetMib
Collisions, Excessive Collisions, MAC
Counter1
TX Errors, Carrier Sense Errors, Frame
UDINT
Too Long, MAC RX Errors
EthernetMib
Counter2
...
WORD ControlBits 0:
1:
UINT
Interface speed in MBits/s: 10,100,...,
ForcedInterface
if Auto-negotiation disabled
Speed
USINT
Type of interface:
0: Unknown interface type
1: The interface is internal
2: Twisted-pair
3: Optical fiber
Link State (0=No link, 1=Link)
Duplex mode (0=Half, 1=Full)
Auto-Negotiation Status
0x0=Auto-Negotiation in progress
0x1=Auto-Negotiation failed
0x2=Failed but speed detected
0x3=Auto-Negotiation success
0x4=No Auto-Negotiation
Manual configuration require reset
(always 0 because it is not
needed)
Hardware error
Control Bits:
Auto-negotiation enable/disable
(0=disable, 1=enable)
Duplex mode (0=Half, 1=Full),
if Auto-negotiation disabled
UM Config RSPE