For contractors
Only contractors must install the appliance and make the electrical connection in full compliance with these
installation instructions.
2.1

Appliance layout

1 Temperature selector
3
5 Power cable
7 Protective pipe for high limit safety cut-out
with reset function
2.2
Appliance description
!
Only use taps suitable for open vented (unpressurised) water heaters.
2.3
Specification
Type
Production no.
Application
"ThermoStop" function
Rated capacity
Type
Weight
Heating output
Voltage
Max. flow rate
Protection level to DIN EN 60529
Power cable with plug
Temperature setting range (infinitely adjustable)
Table 1
and spare parts intended for the appliance.
pliance) ensure that all poles can be separated from the power supply with a contact separation of at least
3 mm.
Installation with direct (permanent) power cables is not permitted.
!
If the water connections at the appliance are interchanged, the heater will become inoperative and com-
ponents may be damaged.
A
-
B
Huz 5 ÖKO Comfort
222164
222166
Undersink
Installed
5 l
Open vented
3.1 kg
See type plate
230 V
5 l/min
IP 24 D
Approx. 600 mm
Approx. 35 °C - 85 °C
2 Indicator
4 DHW connection (red)
6
8 Protective pipe for thermostat
9 Type plate
Hoz 5 Comfort
222154
222155
Oversink
-
5 l
Open vented
3.1 kg
See type plate
230 V
5 l/min
IP 24 D
Approx. 600 mm
Approx. 35 °C - 85 °C
-
15