Herunterladen Inhalt Inhalt Diese Seite drucken

Electrolux EKK6130AO Benutzerinformation Seite 28

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

28 www.electrolux.com
1) To change the gas type, you need to supply the injectors separately.
12.1 Location of the appliance
You can install your freestanding appli-
ance with cabinets on one or two sides
and in the corner.
Minimum distances
Dimen-
sion
A
B
12.2 Gas Connection
Choose fixed connections or use a flexible
pipe in stainless steel in compliance with
the regulation in force. If you use flexible
metallic pipes, be careful they do not
come in touch with mobile parts or they
are not squeezed.
12.3 Flexible nonmetal pipes
connection
If it is possible to easily control the con-
nection in its full area, you can use a flexi-
ble pipe. The flexible pipe must be tightly
attached by clamps.
Installation: use the pipe holder. Always
engage the gasket. Then continue with
the gas connection. The flexible pipe is
prepared for apply when:
– it can not get hot more than room tem-
perature, higher than 30 °C;
– it is no longer than 1500 mm;
– it shows no throttles;
All manuals and user guides at all-guides.com
BURNER
Injector mark 1/100
mm
B
A
A
mm
2
685
Auxiliary
Semi-rapid
127
195
– it is not subject to traction or torsion;
– it does not get in touch with cutting
edges or corners;
– it can be easily examined in order to
check its condition.
The control of preservation of the flexible
pipe consists in checking that:
– it does not show cracks, cuts, marks of
burnings on the two ends and on its full
length;
– the material is not hardened, but shows
its correct elasticity;
– the fastening clamps are not rusted;
– expired term is not due.
If one or more defects are visible, do not
repair the pipe, but replace it.
When installation is complete,
make sure that the seal of each
pipe fitting is correct. Use a soapy
solution, not a flame!
The gas supply ramp is on the rear side of
the control panel.
WARNING!
Before gas connection discon-
nect the mains plug from the
mains socket or switch off the
fuse in the fuse box. Close the
primary valve of the gas sup-
ply.
A
B
A)
Gas connection point (only one point
is applicable for appliance)
B)
Gasket
C)
Adjustable connection
Triple
348
C
E
D

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis