Troubleshooting before the pressing sequence
Fault
The pressing tool cannot
be started and no LED
lights up
Green LED flashes
Troubleshooting during the pressing sequence
Fault
Green LED flashes and
roller drive moves back to
its starting position
Green LED flashes
Red LED flashes
26
Cause
Rechargeable battery is
defective
Rechargeable battery is
not inserted
Retaining pin is not pushed
in correctly
Cause
Retaining pin has come
loose
Rechargeable battery not
charged up sufficiently
Start button was released
too soon
Unlocking button was
pressed or pressing tool
was not in starting position
Pressing tool is outside of
the operating temperature
Actions
Have the rechargeable battery
examined by a repair shop and
replace it if necessary
Insert the rechargeable battery
Push the retaining pin in until the
stop position is reached
Actions
Examine the retaining pin for
damage
Push the retaining pin in until the
stop position is reached: green
LED lights up
Examine the pressfitting for
tightness and repeat the
pressing operation if necessary
Charge the rechargeable battery
or replace it
Press unlocking button: roller
drive moves to its starting
position
Repeat the pressing operation:
press the start button for about
two seconds
Release start button
Press unlocking button: roller
drive moves to its starting
position
Repeat the pressing operation
Bring the pressing tool into a
warmer/cooler environment
Bring the pressing tool to the
required operating temperature
by performing multiple blank
pressing operations
B971-003 © 06-2015