Overview of malfunctions

Feature
Fastener
driving tool
is losing air.
Operating
pressure too
high.
Nails are not
being driven
in
completely.
No nails are
driven in
when the
fastener
driving tool
is triggered.
Possible cause
A seal is faulty.
Safety valve or
check valve
faulty.
Too much
compressed air
was loaded
from the
cartridge.
A valve is faulty.
Operating
pressure is too
low.
The material
you are using is
too hard.
The insertion
depth is set too
low for the
material.
The magazine
or shot channel
are dirty.
Wrong nails are
loaded in the
magazine.
Remedy
▶ Contact Customer Service (see
page 75).
If this occurs sporadically no measures are
necessary. Excessive pressure in the
compression chamber is diverted in the
tool by a safety valve.
If the problem occurs continuously:
▶ Contact Customer Service (see
page 75).
▶ Add more compressed air from the
cartridge (see page 32).
If the problem occurs continuously:
▶ Contact Customer Service (see
page 75).
The nails may only be driven into wood
materials with a maximum strength of
C30 in accordance with EN 338.
▶ Increase the insertion depth (see
page 47).
▶ Turn off the tool.
▶ Remove the magazine.
▶ Remove foreign objects from the shot
channel and magazine.
▶ Emptying the magazine.
▶ Fill the magazine with nails that are
permitted for the magazine (see
page 27).
Eliminating malfunctions
67