Special functions

Low start (Low Start):
The lamp will not start at maximum power as by default, but at the lowest stage.
Double click (Dbl Click):
The lamp may only be switched on with a quick double click. Useful for anybody who wants to avoid that the
lamp is switched on accidentally in particular during transport (e. g. in a backpack).
Stealth mode (Stealth):
The discharged battery capacity and battery warning, usually indicated by the button's LEDs, are partly deacti-
vated. The LED indications will be reduced to a minimum.
Alpine SOS and SOS:
The light will continue with SOS until the battery is empty. The switch will glow pink.
Note: The SOS sign is an emergency signal! Misuse may be prosecuted!
Disorientation Flash 15hz: (3-step Flash)
This mode is extremely irritating and may by no means be misused.
RVLR: (3-step RVLR)
This mode includes an additional slow flash mode.
Police-Mode (Special-Mode):
The lamp only lights up, while the button is kept pressed. The lamp stops shining, when you get off the button.
To prevent an activation by mistake, this mode is chosen in a special way. Press the button 8 times quickly
during 2.5 – 3 seconds. To change back to the standard mode, press the button again 8 times quickly.
20
Connecting:
Plug the included Piko TL charger into an outlet and connect it to the battery.
Charging:
Charging starts automatically. The battery can be left plugged into the charger for an indefinite period.
Although this will not damage the battery, it is not advisable for Li-Ion batteries since they do not
require conservation charging. When kept in a cool place, the annual self-discharging rate for such
batteries is 15 %.
LED display:
LED red on:
charging
LED green on:
battery is fully charged
 Warning! This charger is to be used to charge rechargeable Li-Ion batteries only.
It is NOT suitable for charging NiMH batteries!
 Do NOT use non-rechargeable batteries. – Risk of explosion!
 This charger may be opened ONLY by the manufacturer!