4.3 Oil changing and maintenance cycles
For every day service, the tool has to be cleaned and dried after each use. The battery cartridge and the charging
unit have to be protected against humidity and dust.
The pump has an oil plug with inspection glass which can be used to determine the proper oil level. If the oil level
should be too low the reservoir must be refi lled.
The following hydraulic oils are suitable for a temperature range -12°C to +40°C:
Hydraulic oils based on Ester: Rivolta S.B.H. 11, Shell Naturell HF-E 15
Mineral oils: Shell Tellus T 15, AVIA HVI 15, Mobil DTE 11, NUTO H 15, Rando HD - Z15, Agip OSO 15, BP Energol
HLP 15.
Other equivalent hydraulic oils can also be used.
The hydraulic hose and the armature must be checked for damage and leakage.
Attention
Maintain power tools thoroughly. Check for functionality or jamming of moving parts, breakage of parts and
any other condition that may aff ect the power tools operation.
The battery-hydraulic pump is equipped with a controller enabling the user to see when the next service is due by
fl ashing for 20 sec. at the end of a working cycle. When the next service is due after 10,000 cycles, the unit must be
returned to an authorized service center (ASC). Failure to observe this request results in losing the Warranty. Pre-
ventive maintenance serves your safety. Within the determined use of the tool only the batteries are permitted to be
changed by the customers.
Attention
Do not damage the seals of the tool
Attention
Have the power tool repaired by a qualifi ed expert or by an authorized service center (ASC) before use.