Technical data
Accuracy
The specifications are typical values for BIP AD0-... at
room temperature. The BIP reaches its full accuracy after a
warm-up period of 15 min under constant ambient
conditions. The duration of warm-up depends on the
ambient conditions.
Measuring range S
l
BIP AD0-...-507
BIP AD0-...-508
BIP AD0-...-510
Linearity range S
l
BIP AD0-...-507
BIP AD0-...-508
BIP AD0-...-510
Max. non-linearity
Reference distance S
e
BIP AD0-...-507
BIP AD0-...-508
BIP AD0-...-510
Repeat accuracy
Sampling rate
Response time
Ambient conditions
1)
Ambient temperature T
a
Storage temperature
Temperature drift max. from end
value
Degree of protection per IEC 60529
Shock rating
per EN 60068-2-27
Vibration load
per EN 60068-2-6
Degree of contamination
Supply voltage (external)
Operating voltage U
, stabilized
B
Rated operating voltage U
e
No-load current I
at U
o
e
Residual ripple (% of U
)
e
Rated insulation voltage U
I
Short-circuit protection
Protected against miswiring
Polarity reversal protected
Output
Output voltage at S
l
BIP AD0-...-507/508
BIP AD0-...-510
Output voltage at S
e
Load resistance R
L
www.balluff.com
0...7 mm
7...14 mm
1.5...12.5 mm
0...7 mm
7...14 mm
1.5...12.5 mm
±250 µm
8.5 mm
3.5 mm
10.5 mm
7 mm
±50 µm
≥ 600 Hz
2.5 ms
–25...+70 °C
–40...+85 °C
±3 %
IP67
30 g/11 ms
55 Hz, 1 mm
amplitude,
3 × 30 min
3
2)
15...30 V DC
24 V DC
≤ 20 mA
≤ 10 %
75 V DC
Yes
Yes
Yes
0...10 V
1...9 V
5 V
≥ 2000 Ω
Mechanical
Connection type
BIP AD0-...-EP_ _-507/508/510
BIP AD0-...-EP_ _-S4-507/508/510
Housing material
Tightening torque
Sensing surface, material
Cable connection
Cable jacket, material
Cable diameter
Number of conductors
Wire cross-section
Shielding
Bending radius, fixed cable
1) For UL: Use in enclosed spaces and up to a height of 2000 m above sea
level.
2) For UL: The BIP must be externally connected via a limited-energy circuit
as defined in UL 61010-1, a low-power source as defined in UL 60950-1
or a class 2 power supply as defined in UL 1310 or UL 1585.
A PELV power supply unit must be used for safety-related applications.

Accessories

BAM TG-XE-001 target (order code: BAM01CP)
Material:
Steel
10
BAM TG-XE-002 target (order code: BAM01CR)
Material:
Steel
9
4
5
18
BAE PD-XE-005 calibration box
(order code: BAE00T3)
Cable
Cable with S4
connector
PA
0.5 Nm
PA
PUR
≤ 3.5 mm
3
0.14 mm²
No
≥ 3 x cable
diameter
27
5
9
english
3