Herunterladen Inhalt Inhalt Diese Seite drucken

List Of Error Codes - OEG 650 001 127 Montage- Und Bedienungsanleitung

Schwimmbad-wärmepumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Code
Fault
P3
Malfunction of temperature
sensor at water intake
Malfunction of temperature
P4
sensor at water outlet
Malfunction of temperature
P1
sens
or for de-icing
Malfunction of external tem-
P7
perature sensor
Malfunction of sensor at air
P2
outlet
P8
Water temperature at outlet
too low for cooling mode
PC
Antifreeze protection
E4
High pressure protection
P9
Low pressure protection
PL
Malfunction flow sensor
P6
Excessive temperature diffe-
rence between water inlet
temperature
and water outlet temperature
for cooling mode
E3
Vented air temperature too
high
E6
Thermal protection
Problems with connection bet-
E8
ween PCB and controller
Swimming pool heat pump
Possible causes
1. Sensor badly connected
2. Sensor defective
3. PCB defective
Same causes as P3
1. Flow rate too low
2. Water temperature at intake too low
3. PCB defective
Protection activated when ambient tempe-
rature is too low and unit is on standby.
1. Insufficient water flow
2. Defective 4-way valve or excess
refrigerant
3. Water temperature setting too high
4. Pressure switch disconnected or
defective
5. PCB defective
1. Insufficient refrigerant
2. Defective 4-way valve
3. Pressure switch disconnected or
defective
4. PCB defective
1. Water flow rate too low
2. Defective water flow sensor
3. PCB defective
1. Water flow rate too low
2. PCB defective
Insufficient refrigerant gas
Same causes as fault E4
1. Water flow rate too low or water intake
temperature too high
2. Defective thermal protection
3. Bad connection
4. PCB defective
1. Bad connection
2. Wired controller defective
3. PCB defective
Troubleshooting
1. Reconnect sensor
2. Replace sensor
3. Replace PCB
Same measures as P3
1. Check water filter and hydraulic circuit
(no cloggings)
2. Adjust temperature
3. Replace PCB
No intervention necessary
1. Check water pump operation or adjust
regulating valve
2. Refill refrigerant
3. Lower water temperature
4. Reconnect or replace pressure switch
5. Replace PCB
1. Refill refrigerant
2. Replace valve
3. Connect or replace pressure switch
4. Replace PCB
1. Check your water circuit operation and
the opening of the bypass valves
2. Replace water flow contactor
3. Replace PCB
1. Check your water circuit operation and
the opening of the bypass valves
2. Replace PCB
1. Refill refrigerant
2. Same measures as fault E4
1. Check water flow rate or adjust water
temperature
2. Replace circuit breaker
3. Check connections
4. Replace PCB
1. Check wiring connection between
controller and PCB
2. Replace controller
3. Replace PCB
75

List of error codes

7.2
GB

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading