Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Instructions - OEG 650 001 127 Montage- Und Bedienungsanleitung

Schwimmbad-wärmepumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

46
During use
1.2

Safety instructions

To avoid serious injuries, you should never touch the fan when it is operating.
Make sure that the heat pump is kept out of the reach of children to avoid serious
injuries caused by the blades of the heat exchanger.
Never start the equipment if there is no water in the swimming pool or if the circulation
pump is stopped.
Check the water flow rate once a month and clean the filter if required.
During cleaning
Prior to cleaning, turn off the power supply of the equipment. Close all water inlet
and outlet valves.
Do not insert anything into the air or water intakes or outlets.
Do not rinse the equipment with water to prevent the risk of electric shock.
During repairs
Works on the refrigerant system must be carried out in accordance with currently
applicable safety regulations.
Brazing should be done by a qualified welder.
Only genuine spare parts may be installed.
When replacing pipework, only copper pipes conforming to standard NF EN 12735-1
may be used for repairs.
Notes for detecting leaks when pressure testing:
To avoid the risk of fire or explosion, oxygen or dry air must never be used.
Instead, use dehydrated nitrogen or a mixture of nitrogen and refrigerant.
The low and high side test pressure must not exceed 42 bar.
GB
Swimming pool heat pump

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis