Herunterladen Inhalt Inhalt Diese Seite drucken

Special Procedures In Case Of Failures; Replacement Of Heating Elements - TECNOINOX B FAE9-Serie Gebrauchs- Und Installationsanleitung

Elektrische kippbratpfannen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
-
If the appliance should not work properly during use, turn it off immediately and close or cut off all supplies (electrical power supply and water).
-
Apply to a service centre for help.
-
The manufacturer shall not be held responsible nor has any warranty commitments for damage caused by non-compliance
with prescriptions or by installation not in conformity with instructions. he same applies in case of improper use or
different application by the operator.
-
Maintenance operations and repairs must be performed only by specialists!
After having removed the control knob, remove the control panel, the handle of water inlet tap and the handwheel for tilting of pan.
R
EPLACEMENT OF HEATING ELEMENTS
Disconnect the electric cables to heating elements.
-
Remove the front fixed panel and the steady pin of the tilting pan lever..
-
Rotate the pan in the max. opening.
-
Remove the insulation protection , unloosing the fixing screws to the pan.
-
Remove the protection panel of heating elements.
-
Remove the heating element support plate from damaged heating element.
-
Fit the new heating element operating in the opposite order.
-
R
EPLACEMENT OF SIGNAL LAMP
Disconnect the power cables.
-
Remove the signal lamp, unscrewing the fixed to the control pane .
-
Fit the new signal lamp in the reverse order of operation.
-
R
EPLACEMENT OF WORKING OR SAFETY THERMOSTAT
Disconnect power cables, after having removed the front panel.
-
Remove the insulation protection, unloosing the fixing screws to the pan.
-
Remove the protection panel of heating elements.
-
Remove the support plate of central heating element.
-
Remove the central heating element and then the fixing bulb boss.
-
Replacing the new thermostat be careful about tightening of the boss on the bulbs.
-
If the bulbs would be squeezed, this would cause the damage of thermostat.
R
EPLACEMENT OF THE SWITCH
-
Disconnect the power cables, after having removed the front panel.
-
Replace the switch uloosing the fixing screws to the support , after having taken off the coaxial working thermostat.
Fit the new switch in the reverse order of operation.
-

SPECIAL PROCEDURES IN CASE OF FAILURES

HOW TO PROCEED, IF ...
DISCONNECT THE APPLIANCE (REMOVE THE FUSE)
5410.296.00

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

B fie9-serieB8fae9B8fie9B12fae9B12fie9

Inhaltsverzeichnis