CHANGING THE CONTROL SETS:

When rSl or iSl are displayed, hold the key
arrow keys
and then press the key

LEDS AND ALARMS:

pressed unit the label on display flashes. At this point use the
to confirm.
Alarm active
Hour or time
Temperature expressed in C or F.
Room probe failure. Check the connections or change the room probe.
Evaporator probe failure. Check the connections or change the evaporator
probe.
Needle probe failure. If continuously is displayed, clean the probe. If the
problem continues change the probe. (if the screen shows ip3 / end, it means
that the temperature-controlled cycle is finished successfully). In time
controlled cycle normally you will see this alarm.
Real time and clock data-lost. Set the time/clock of the product. Press the
for 5 seconds. The by using SET key, set the clock as follows: Min: Minutes, Hou:
Hour, dAy: Day, Mon: Month, yEA: Year. tiM: Time format , EU or USA.
Real time clock failure. Reset the clock settings. If alarm continues call
authorized service.
Maximum temperature alarm. Check the temperature of the cabinet.
While loading to close the air blowing canals of the product. Make sure you load
the products as it is shown in the user manual.
The evaporator fan is not working.
The door is left open. Make sure you load the products as it is shown in the user
manual. Make sure that the door is closed and sealed completely.
Minimum temperature alarm. Check the temperature of the cabinet.
Digital thermostat failure. Please contact with technical service