Indicative handling volume [m³]
Condensate capacity [L/24hour]
Working temperature [°C]
Working humidity [%R.H.]
Air flow [m³/hour]
Power supply voltage
Current absorption [A]
Power absorption [W]
Power absorption in standby (max) [W]
Refrigerating gas charge [g]
Refrigerating circuit maximum pressure [MPa]
Noise level at 1 meter distance [dBa]
Dimensions: w×h×d [mm]
Condensate collection tank capacity [L]
Tab.A – Technical data table
Symbols
B
This symbol indicates that the appliance has
been loaded with flammable refrigerant gas.
D
Read this manual carefully.
A
Operator's manual, instructions for operation
and routine maintenance.
E
ATTENTION: every notes under this symbol
will evidence dangerous conditions that can
cause problems to persons and thinks if not
made in the right way. Follow carefully the
description.
C
Important note: notes will evidence condi-
tions and features that can make easier and
better the use of the unit.
F
DANGER, live electrical parts
8
ECODRY 625
17.2
(*)
(**)
+5 / +32
40 / 95
230 V, 50 Hz
1.32
(*)
(**)
292
(*)
(**)
See label on board
Refrigerating gas
398×555×382
Weight [Kg]
aT 25°C e 65 %R.H.
at 30°C / 80% R.H.
(*)
(**)

General safety rules

D
400
Keep and consult this manual carefully as all the
27.6
warnings provide important safety information
during installation, use and maintenance.
B
300
This appliance contains flammable pressurized
refrigerant: any maintenance concerning the
refrigerant circuit must be carried out by technical
1.55
personnel who have a valid certificate issued by
350
an accredited organization, which certifies their
2
competence to operate safely with this type of
refrigerants.
R290
• The refrigerant fluid is odourless: if you suspect that there is a re-
frigerant gas leak, properly ventilate the room before doing anything
1.8
else.
54
• The appliance must be placed in a room where there are NO sources
of ignition continuously operating (for example: open flames, electric
or gas heaters).
28,7
• This dehumidifier is NOT intended for people, children included,
6
with limited physical or mental capabilities or without enough ex-
perience concerning the use of it. Keep it away from children and
animals.
• This dehumidifier SHOULD not operate in rooms where a danger of
explosion exists.
• Do NOT use this dehumidifier in environments with air containing
oil, sulphur or chlorine.
• Keep always the inlet and outlet air grids free (10 centimetres at least).
• The appliance must always operate in a vertical position with the four
wheels turned downwards.
• Do NOT move the dehumidifier when working.
• To move the dehumidifier switch it off and empty the condensate
tank.
• Do NOT put any tool inside the unit.
• Do not puncture or burn.
F
This appliance must be connected to a grounded
electrical system. Make sure that the power supply
voltage corresponds to he one indicated in Tab.A, that
the electrical system complies with current regulations
and is adequately protected.
• Do NOT use the dehumidifier in different ways other then the one
described in this manual.
E
ATTENTION: any maintenance on the refrigerating
or electric circuit must be made only by experienced
and qualified staff.
Introduction
The appliances of the ECODRY series are air dehumidifiers that remove
the humidity from the environment. They are equipped with a refriger-
ating circuit and the new electronic control performs all the functions
included automatic start and stop and defrosting cycle if necessary.
These dehumidifiers were designed for a domestic an not industrial use.