You can remedy most of the faults and errors that can occur in daily operation yourself. In many cases, you
will be able to save time and cost as you do not have to call technical service. The following table is intended
to help you understand the causes of an error and how to rectify it.
Problem
The display is dark.
The Verdanium
tricity.
The display shows "insufficient
The water supply is insufficient.
water".
The Verdanium
enough water.
No water is coming out of the with-
The water supply is interrupted.
drawal tap.
The Verdanium
enough water.
The tube to the withdrawal tap has
a kink.
Unusual pump noise.
No error! Slurping sounds at the beginning and at the end of water pro-
duction is normal.
Water from the Verdanium
Home
No error! These are oxygen and hydrogen bubbles which can arise during
is milky.
the reverse osmosis. It is a sign of excellent filtration!
Water from the Verdanium
Home
After the initial commissioning, the
recommended additional 7 - 10
contains sediments after the initial
commissioning.
minutes of operation have not been
adhered to.
Wastewater runs without interrup-
Check all devices connected to the
tion into the drain.
Verdanium
Home
There is little water coming out of
- Another connected device is with-
the withdrawal tap.
drawing water at the same time.
- The reverse osmosis membranes
may be blocked.
Water runs into the drain after the
No error! The Verdanium
withdrawal tap has been closed.
king water during the next usage.
The Verdanium
Home
operates
One of the pressure sensors in the
Home
without interruption although all
Verdanium
connected devices do not withdraw
water.
*
Authorised service provider:
https://www.vision-aqua.ch/intern/authorised-retailer-section/find-an-authorized-retailer/
62
Instruction Manual – Verdanium Home – Ver. 2.2.1 – 04.2021
Cause
Solution
Home
Please check:
has no elec-
- The power cable is plugged-in
- Main switch setting is on (I)
- The fuse is OK
- Power outlet has electricity
Please check:
Home
- The water supply (angle valve) is
receives not
open
- Minimum water pressure of 150
kPa (1.5 bar) is available
- The water supply tube 3/8" has no
kinks
- The filter is not blocked
- The pre-filters are correctly instal-
led.
Please check:
Home
- The water supply (angle valve) is
receives not
open
- Minimum water pressure of 150
kPa (1.5 bar) is available
- The water supply tube 1/4" to the
withdrawal tap has no kinks
- The power cable is plugged-in
- Main switch setting is on (I)
- The fuse is OK
Open the withdrawal tap of the
Home
Verdanium
and operate the
filter for 7 – 10 minutes.
Disconnect water supply.
.
Contact authorised service provi-
der
*
In case of blocked membranes,
please contact your authorised
service provider.
Home
is rinsing itself to produce ultra-pure drin-
Disconnect the power cord and clo-
se the water supply (angle valve).
may be damaged.
Contact your authorised service
provider.

Standard scope of delivery

Verdanium Home
Power cord, Europe CEE 7/7
Item No.: 9000001
to C13, 0,75mm², 1,8m
Item No.: 1000084

Optional Accessories

Plastic tube - 3/8" -
Plastic tube - 1/4" -
Colour: blue
Colour: natural
Item No.: PE-12-EI-0500F-B
Item No.: PE-08-BI-0500F-N
Plastic tube - 3/8" -
Colour: natural
Item No.: PE-12-EI-0500F-N
1-way withdrawal tap,
3-way withdrawal tap,
stainless steel
stainless steel
Item No.: 1000146
Item No.: 7000028
Instruction Manual – Verdanium Home – Ver. 2.2.1 – 04.2021

Scope of delivery

Power cord, Swiss, Type J to C13,
0.75mm², 1.8m (Accessory)
Item No.: 1000083
Plastic tube - 1/4" -
Colour: red
Item No.: PE-08-BI-0500F-R
Hydro-Stopper, water-leak
detector, water stopper with
two sensors
Item No.: 1000016
63