Herunterladen Diese Seite drucken

Belden Hirschmann OCTOPUS HiOS-2A Referenzhandbuch Seite 943

Vorschau ausblenden Andere Handbücher für Hirschmann OCTOPUS HiOS-2A:

Werbung

Industrieprotokolle
16.4 PROFINET
Tab. 69:
Byte Content
15
Not used
16
Not used
17
Connection
Tab. 70:
Byte Content
0
Report port error
1
Report connection
error
2
Transmission rate
too high
3
Port on
4
Link status
5
Bit rate
6
Duplex
7
Autonegotiation
398
Gerätestatus
Access
ro
Port-Status/Port-Parameter
Access
rw
rw
rw
rw
ro
ro
ro
ro
Value
Meaning
0
1
2
0
1
2
0
Unavailable
1
OK
2
Connection failure.
Value
Meaning
0
Do not send alarm
1
When one of the following alarm reasons occurs,
send an alarm.
0
Do not send alarm
1
Send alarm if the connection has failed.
0
Do not send alarm
1
Send alarm if the threshold value for the
temperature has been exceeded.
0
Unavailable
1
Switched on
2
Switched off
0
Unavailable
1
Connection exists
2
Connection interrupted
0
Unavailable
1
Unknown
2
10 MBit/s
2
100 MBit/s
2
1000 MBit/s
0
Half duplex
1
Full duplexFull duplex
2
0
Unavailable
1
off
2
on
UM Config OCTOPUS
Release 8.6 12/2020

Werbung

loading