Tab. 59:
Id
Attribute
0x6
Port Monitor
B
0x6
Quick Connect
C
0x6
SFP Diagnostics
D
UM Config OCTOPUS
Release 8.6 12/2020
Hirschmann-Erweiterungen des Ethernet-Link-Objekts (Forts.)
Access
Rule
Get/Set DWORD
Get/Set USINT
Get
Data type
Description
0: Link Flap (0=Off, 1=On)
1: CRC/Fragment (0=Off, 1=On)
2: Duplex Mismatch (0=Off, 1=On)
3: Overload-Detection (0=Off, 1=On)
4: Link-Speed/ Duplex Mode
5: Deactivate port action (0=Off,
6: Send trap action (0=Off, 1=On)
7: Active Condition (displays which
8:
9:
10
:
11
:
12
:
13
:
14
:
15
:
Quick Connect on the interface
(0=Off, 1=On)
If you enable Quick Connect, then the
device sets the port speed to 100FD,
disables Auto-Negotiation, and
Spanning Tree on the interface.
STRUCT of:
STRING
ModuleType
SHORT-STRING
SerialNumber
USINT Connector
USINT Supported
DINT Temperature in °C
DINT TxPower
in mW
DINT RxPower
in mW
DINT RxPower
in dBm
DINT TxPower
in dBm
Industrieprotokolle
16.3 EtherNet/IP
(0=Off, 1=On)
1=On)
condition caused an action to
occur)
00001
: Link Flap
B
00010
: CRC/Fragments
B
00100
: Duplex Mismatch
B
01000
: Overload-Detection
B
10000
: Link-Speed/ Duplex
B
mode
Reserved (always 0)
Reserved (always 0)