Herunterladen Inhalt Inhalt Diese Seite drucken

Weco 245d Bedienungsanleitung Seite 10

Digimanager
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
Cod. 006.0001.2240
28/04/2021 V.1.1
ENGLISH
CODE
NAME
D1
DISPLAY
S1
LH ARROW
S2
RH ARROW
S3
+
S4
-
The display shows the items of the main menu set up in the welding machine control panel.
The following parameters can be set:
(MIG/MAG)
U
Welding voltage
23.6
Sets the welding voltage.
(MIG/MAG)
I
Welding current
120
Sets the welding current.
(MIG/MAG)
Wire speed
6.4
Sets the wire speed for welding.
(MIG/MAG)
Material thickness
3.0
Sets the thickness of the material to be welded.
(MIG/MAG)
Arc length correction
0.0
Sets up the welding arc length correction in relation to the preset value from the
synergic curve.
(MIG/MAG)
0
Dynamic (in the pulsed process)
Corrects the energy of the pulsed arc pulses.
(MIG/MAG)
0
Inductance (in the short-spray process)
Changes the energy when a short circuit occurs.
(MIG/MAG, MMA, ARC AIR, TIG LIFT)
0
Selected JOB
Displays the currently loaded JOB.
If no JOBs are loaded yet, the display will show "
10
WELD THE WORLD
DESCRIPTION
The display shows the selected parameter and its value.
Selects on the power supply the desired parameter by scrolling to the left.
Selects on the power supply the desired parameter by scrolling to the
right.
The key increases the value of the selected parameter.
The key decreases the value of the selected parameter.
Digimanager 245d-505d-555d
- - -
"
RC-08d

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

505d555d

Inhaltsverzeichnis