6

Malfunction remedy

Malfunction
The unit does not switch on
The vacuum does not start up
The suction power is reduced
The vacuum switches on and off
Insufficient or no discharge pump
delivery.
The discharge pump does not start up
automatically.
7

Maintenance and cleaning

W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
Isolate the device (disconnect from the power supply) before carrying out any work on it.
The following conditions must be met:
The plug connectors of the helix cables are connected on delivery.
– The plug connectors do not need to be disconnected for cleaning and maintenance.
Before opening the unit always switch it off and disconnect the power plug.
Do not lift the discharge pump out of the tank. The connection cable can be damaged.
Never deposit the vacuum head on the filter element (in order to avoid damage). Place the vacuum
head on its side or with the handle at the bottom.
Cause
No mains voltage
The carbon brushes are worn
The telescopic wand with vacuum attachment
has been submerged too deep
Suction hose or vacuum attachment is soiled
The discharge pump is switched off and the
non-return valve is clogged
This occurs when the tank is empty when it is
switched on
Max. water level is exceeded
The motor (overload) protection switch has
tripped
The pump inlet is clogged
The discharge hose is causing water
backpressure
Water level sensors are soiled
The plug connectors are not correctly
connected
Remedy
Switch on mains voltage
If the carbon brushes become worn, please
send the unit head to OASE for repair.
Adhere to max. submersion depth of 2.60 m
Clean
Clean
Vacuum up water with the discharge hose until the
valve has been rinsed clean
Clean the non-return valve
Normal behaviour
The vacuum and discharge pump have to adjust to
each other
Empty the tank
Clean the discharge pump
Route the discharge hose without kinks
Empty the tank
Clean the pump
Press the unlock button
Clean
Route the discharge hose without kinks
Clean
Connect, tighten the union nuts
- EN -