Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
- EN -
Wall or floor installation
The supplied holding fixture is intended for fastening the spotlight, either on a stable wall or on the ground (stable sub-
strate).
• It is not permissible to fasten the driver to the ceiling.
How to proceed:
 C
1. Drill two holes with the indicated spacing.
2. Fasten the holding fixture.
– Use suitable fastening materials.
3. Insert a square nut into the spotlight on both sides.
4. Turn the clamping screws into the square nuts by several rotations on both sides, then insert the spotlight in the
holding fixture.
– If necessary, adjust the tilt of the spotlight. (→ Adjusting the tilt of the spotlight)
5. Tighten the clamping screws.
Adjusting the tilt of the spotlight
How to proceed:
 D
1. Loosen the clamping screws on the spotlight on both sides.
2. Tilt the spotlight as required.
3. Retighten the clamping screws.
Establishing the connections
 F
• Each spotlight can be connected to the driver directly or with the aid of one or more 10 m LunAqua Power LED
extension cables (42636). The maximum cable length between spotlight and driver must not exceed 45 m.
• Do not exceed the max. connected load of the driver. (→ Driver operating manual)
• This figure shows an example of how to connect spotlights to a driver. Depending on the spotlight and the driver,
different connection variants are possible.
How to proceed:
 E
1. Remove the protection cap from the driver.
2. Fit the plug connector and secure with the two screws (max. 2.0 Nm).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
Commissioning/start-up
The spotlight is controlled via the driver. (→ Operating manual of the OASE driver in use)

Remedy of faults

Malfunction
Spotlight is not lit
Strength of the spotlight decreased
Water in the spotlight housing
14
Cause
Spotlight not connected / no supply voltage
Driver defective
Spotlight defective
Lamp glass soiled
In the event of severe heat build-up, the
strength of the light is automatically reduced by
the over temperature protection system
Seal defective
Remedy
Check all cables and connections.
Replace the driver.
Replace the spotlight.
Clean lamp glass
Allow the spotlight to cool down. Keep away
from additional heat sources
Check seal

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis