7.1

Cleaning the tank

How to proceed:
 D
1. Undo the locking clips on the adapter ring.
2. Lift the suction head by the handle.
3. Clean the following parts with clean water and a soft brush:
– Water level sensors
– Pump inlet
– 2" Storz coupling type C
– Inside of the tank
4. Reassemble the unit in the reverse order.
7.2

Cleaning the non-return valve

Prerequisite: Vacuum head with adapter ring has been removed.
How to proceed:
 E
1. Release the hose clip on the connection element and pull off the pump.
2. Twist off the non-return valve by turning it counter-clockwise.
3. Clean using clean water and a soft brush.
4. Assemble the parts in the reverse order.
7.3

Cleaning the filter element

Prerequisite: Vacuum head with adapter ring has been removed.
How to proceed:
 F
1. Turn the filter support base counter-clockwise.
2. Pull off the filter support base and filter, and clean using clean water and a soft brush.
3. Check the floats in the filter support basket. Ensure that they can move freely.
4. Assemble the parts in the reverse order.