Herunterladen Inhalt Inhalt Diese Seite drucken

General Aspects; Scope Of Delivery - HEYLO HL 800 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für HL 800:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1. General aspects

ATTENTION: Always read before commissioning!
Please carefully follow the instructions in the operating manual. Non-observance will invalidate the
warranty. The manufacturer accepts no liability for any damage or consequential damage arising from
this.
The HL 800 is a mobile air cleaning unit. The air is drawn in from the environment and passed through a
four-stage filtration system. The filter stages consist of a pre-filter, one 2in1 combination-filters for gases
and particles as well as a plasma generator.
The individual stages have the following functions:
1st stage
Prefilter
A washable plastic filter is used as a pre-filter. The pre-filter filters coarse dust particles of more than 5
micrometers, such as house dust, scales, pollen. The filter can be washed out with water and can
therefore be used several times. HEYLO recommends replacing the pre-filter annually.
2nd + 3rd stage
Effective formaldehyde filter
The formaldehyde filter with activated carbon cleans the air of unwanted odours, gases and substances. It
also cleans the air of harmful formaldehyde in a very short time. The substances are absorbed by the
activated carbon and when the filter is saturated, it must be replaced. HEYLO recommends this every 6
months.
In case of strong odour pollution, such as cigarette smoke, a more frequent change may also be advisable.
Highly efficient HEPA filter (suspended matter filter)
The HEPA filter filters airborne germs, smoke, and dust particles down to 1µm in size at a rate of 99% or
more. In combination with the multifunctional filter, the HEPA filter can filter out microscopic particles
with a diameter of more than 20 nanometres, including bacterial mould, dust, allergens, and some
viruses. According to the World Health Organisation, the corona virus, avian flu virus, influenza virus and
legionella bacteria are larger than 20 nanometres
4th stage
Ionization
By applying strong electric fields, ionizers can electrically charge individual air particles and thus increase
the ion concentration in the room air. The charged particles are more reactive and can thus destroy odour
molecules and other pollutants. At the same time, differently charged particles attract each other and
form larger lumps that sink to the ground faster and can be filtered out of the air more easily.

2. Scope of delivery

1 x air cleaner HL 800
1 x pre-filter
1 x main filter as combination filter
1 x remote control
1 x instruction manual