Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Location; Connecting The Appliance; Electrical Connection - Bosch KI25R-Serie Gebrauchsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5
The climate class can be found on
the rating plate. Fig. +
Climate class
SN
N
ST
T
Note
The appliance is fully functional
within the room temperature limits
of the indicated climatic class.
If an appliance of climatic class SN
is operated at colder room temperatures,
the appliance will not be damaged up to
a temperature of +5 °C.
Ventilation
Fig. !/16
The refrigeration unit is ventilated only
via the ventilation grille in the base.
Never cover the ventilation grille or
place anything in front of it. Otherwise
the refrigeration unit must work harder,
increasing the power consumption.

Installation location

Install the appliance in a dry, well
ventilated room. The installation location
should neither be exposed to direct
sunlight nor near a heat source,
e. g. a cooker, radiator, etc. If installation
next to a heat source is unavoidable, use
a suitable insulating plate or observe
the following minimum distances to a
heat source:
3 cm to electric or gas cookers.
30 cm to an oil or coal-fired cooker.
Permitted ambient
temperature
+10 °C to 32 °C
+16 °C to 32 °C
+16 °C to 38 °C
+16 °C to 43 °C
Connecting
the appliance
After installing the appliance, wait at least
1 hour until the appliance is switched on.
During transportation the oil in the
compressor may have flowed into the
refrigeration system.
Before switching on the appliance for
the first time, clean the interior of the
appliance (see chapter "Cleaning
the appliance").

Electrical connection

The socket must be near the appliance
and also freely accessible following
installation of the appliance.
The appliance complies with the
protection class I. Connect the appliance
to 220–240 V/50 Hz alternating current
via a correctly installed socket with
protective conductor. The socket must
be fused with a 10 to 16 A fuse.
For appliances operated in
non-European countries, check whether
the stated voltage and current type
match the values of your mains supply.
This information can be found on the
rating plate. Fig. +
m
Warning
Never connect the appliance
to electronic energy saver plugs.
Our appliances can be used with
mains and sine-controlled inverters.
Mains-controlled inverters are
used for photovoltaic systems which
are connected directly to the national
grid. Sine-controlled inverters must be
used for isolated applications (e.g. on
ships or in mountain lodges) which are
not connected directly to the national
grid.