Installation and start-up
Example: 2 x flashing "RF TX" (red)
version "2.5"
If the tamper contact is closed when the control device starts up, the
aforementioned tests will not be performed.
Automatic calibration of the chip key reader
If the DIP switch 6 (chip key reader) is activated when the control device starts up, calibration
will be performed automatically as soon as the LED test is completed and the software version
is displayed.
During the calibration of the chip key reader, the status LEDs for sub-areas 1 to 4
light up one after the other (sequence of lights from top to bottom).
If DIP switch 6 (chip key reader) is deactivated when the control panel starts up, calibration will
be performed as soon as the DIP switch is activated.
The chip key reader re-calibrates itself automatically every 24 hours to
compensate for changes to the environmental conditions and to ensure correct
functioning.
Manual calibration of the chip key reader
You can also start the calibration manually by pressing the
simultaneously. This is required whenever changes to environmental conditions are impeding
the chip key reader's functions.
Keep the chip key and any other metal objects away from the chip key
reader during calibration to avoid disrupting the process.
14 EN
5 x flashing "TEST" (green)
Software
and
keys