Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating Instruction
will display the error message ER01, and the
START/STOP key will have to be pressed, to
EN
resume the normal charge cycle.
Battery testing
The tests within the operating modes may ter-
minate with the signalling of some errors.
Damaged Battery: the "Fault" LED

switches on and the "Start / Stop" LED
switches off, and the charger enters
Stand-by mode. The display shows the
message "Errx" , where 'x' is the num-
ber corresponding to the cause of the
error (see Table 1). Single two second
audible warning.
Polarity reversal: the "Reverse" LED

switches on, and the display shows
the message "Err7" with a two second
audible warning.
www.herthundbuss.com
95950005
Operating Instruction

Error codes

The errors that may be reported are described in Table 1.
Display
indication
Er01
Er02
Er03
Er04
Er05
Er06
Er07 and led
reverse
Er08
20
21
Cause
Solution
Position the clamps correctly and start charging
Leads disconnected, leads
the battery again (see section "Operating Battery
short-circuited.
Charger").
Battery completely short-
Contact your nearest battery service centre.
circuited.
Battery faulty or unrecoverable.
No current accepted after 20
The battery could be defective.
hours of recovery
Remove any objects that could be covering the
Internal overheating of battery
ventilation area of the battery charger or move
charger. Battery charger over-
it to a cooler area. Wait for the battery charger to
load.
start again automatically.
Voltage error.
Set a "Recovery" cycle.
Battery voltage too low. (You
Only use the battery charger with supported 12V
are attempting to charge a 6V
batteries. Start charging the battery again (see
battery).
section "Operating Battery Charger").
One or more elements of
the battery has/have short-
The battery could be defective.
circuited.
Battery voltage too high
Only use the battery charger with supported 12V
compared to that set. (You are
batteries.
attempting to charge a 24V
Start charging the battery again (see section
battery).
"Operating Battery Charger").
Battery capacity excessive. Un-
Use a battery charger with greater capacity.
able to reach end condition.
The clamps of the output leads
Position the clamps correctly and start charging
are not connected correctly to
the battery again (see section "Operating Battery
the battery.
Charger").
Excessively high output current.
Current exceeds maximum
Reduce battery absorption.
limit.