Problem
Flames blow out.
Persistent grease fire.
Flashback –
fire in burner tube(s).
Flare-up
Unable to fill gas
cylinder.
One burner does
not light from other
burner(s).
Note: If your problem is not resolved from the information above, please contact
your local gas dealer.
Possible Cause
High or gusting winds.
Low on LP gas.
Excess flow valve
tripped.
Grease trapped by food
buildup around burner
system.
Burner and burner tubes
are blocked.
Grease buildup.
Excessive fat in meat.
Excessive cooking
temperature.
Some dealers have
older fill nozzles with
worn threads.
Grease buildup or
food particles in end of
carryover tube.
Prevention / Solution
Turn the front of the grill to
face wind or increase flame
height.
Replace the gas cylinder or
have it refilled by your LP gas
dealer.
Refer to "Sudden drop in gas
flow" (above).
Turn knobs to "OFF". Turn gas
off at gas cylinder. Leave lid in
position and let fire burn out.
After grill cools, remove and
clean all parts.
Turn knobs to "OFF". Clean
burner and/or burner
tubes (see "Cleaning and
Maintenance" section).
Clean burners and inside of
grill/firebox.
Trim fat from meat before
grilling.
Turn the knobs anticlockwise
to a lower setting.
Turn worn nozzles do not
have enough "bite" to engage
the valve. Try a second LP gas
dealer.
Clean carry-over tube with
wire brush.