Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
1. DESCRIPTION.
1.1 HELMET: is composed of a fibre shell covered with 3 coats of paint, the last one of
which, the most external one, is polyurethane; a polycarbonate visor;
for KOMPAT88 and PROF88 series a reinforced and padded plastic device is supplied
for weight balance on the operator's shoulders; a polyamide collar which closes
efficiently and comfortably round the operator's neck; a head-band adjustable from 53
to 63 cm (6-5/8 to 7-7/8 hat size).
1.2 BLOWER UNITS: They are composed of an ABS case with socket and ON/OFF
switch; a fan unit actuated by an electric micro motor and an electronic air flow
indicator with alarm for the T8X system.
1.3
HOSE ASSEMBLY:
1.3.1 For respirators with K80 - K80E helmets: it consists of a spiraled hose enclosed by
smooth plastic for easy decontamination.
1.3.2 For respirators with K80S helmets: it consists of a corrugated hose with fittings for
helmet-blower unit connection.
1.4 BATTERY ASSEMBLIES:
1.4.1-LI-870: the pack consists of rechargeable lithium batteries in a sealed ABS housing
with non reversible plug; a circuit protection against short-circuits and over-discharge.
1.4.2 NM300 / 8 battery ass.y (built into T9R blower): It is composed of 8 NI-MH batteries
connected in series.
1.4.3 PROF88-LI and KOMPAT88-LI, 3 rechargeable lithium batteries connected in series.
1.5 FILTERS
1.5.1 ZP3 FILTER: The letter "R" marked on the filter shows that the dust filter or filtering
part of a combined filter can be used for more than one working shift after exposure to
aerosols; the letters "NR" indicate that the use is strictly limited to one working shift.
The filter is made of micro porous technical paper finely pleated with normalized EN
148-1 thread ( see filter use instruction).
1.5.2 ZA2P3 FILTER: it is made of 2 parts - the first of finely pleated submicron technical
paper and the other of activated carbon.
Connection: Thread - meets EN 148-1 standard requirements (see use instructions)
1.6
AIRFLOW INDICATORS:
1.6.1 ELECTRONIC INDICATOR - with audible alarm : mounted on the T8X blower unit for
the powered respirators with K80E helmets.
1.6.2 SPHERE TYPE INDICATOR : for the powered respirators with K80 and K80S
helmets.
2.TECHNICAL FEATURES
2.1
NOISE LEVEL: < 75 dB.
2.2
SPECIFICATIONS:
0313212-L8
K80E T8X-L8
120
0313214-L8
K80S T8-L8
120
0313215
K80S T9
120
0313218-L8
K80 T8-L8
120
0313219
K80S T9R
120
0313216-LI
PROF88-LI
120
0313217-LI
KOMPAT88-LI
160
3.
OPERATION
3.1 The blower unit, powered by rechargeable battery, takes in air through the filters and
sends it, via hose, to the inside of the helmet. The helmet goes into slight positive over
pressure and the wearer breathes filtered air only. Expired air is expelled through the
diaphragm valves.
4.
USE
4.1 For respiratory protection against solid and liquid aerosols if fitted with ZP3 particle
filters.
For respiratory protection against particles, and organic vapours gas and organic
vapors, mist and solid and liquid aerosols if fitted with ZA2P3 combined filters.
The powered respirators are designed for the protection of the respiratory tract of the
wearer and not for other risks such as the protection of the face or eyes.
a)Some uses for which the powered respirators for the protection of the respiratory system
against solid and liquid aerosols (ZP3
• Agriculture: Cleaning stables, pens and coops.
Handling and processing grains and fodder
ISTRUZIONI D'USO – USE INSTRUCTIONS –
GEBRAUCHSANLEITUNG – MODE D'EMPLOI -
INSTRUCCIONES PARA EL USO - Οδηγίες Χρήσης-Instruções

ENGLISH

Lithium
800
7,4
8700 mAh
Lithium
1000
7,4
8700 mAh
Direct power
600
12
supply
Lithium
1000
7,4
8700 mAh
Direct power
12
supply
600
NiMh
9,6
3000 mA/h
Lithium
600
11,1
2600 mAh
Lithium
600
11,1
2600 mAh
filter)
are designed
para o uso
• Chemical and: pharmaceutica, Chemical dusts, formulations and pastes; Biohazardous
operations and infectious diseases.
• Construction, building and renovation: Cutting / polishing / grinding / drilling of
concrete, stone, masonry; Plaster; Painting and surface coating; Masonry work and
renovations; Controlled demolition
• Metal working, Mechanical machining and scrapping,
• Wood working, Cutting / bending / drilling / sanding; Adhesive removal via scraping and
sanding,
• Working with fibreglass and minerals: Mineral mining and marble working.
• Painting: Powder coating and spraying.
b)against solid and liquid aerosols, organic gases and vapors (with ZA2P3 filters):
• Agriculture: Mixing / spraying of pesticides, fungicides, herbicides; Spraying and weeding
using tractor/ service machine; Spraying and weeding using knapsack sprayers; Pesticide
treatments (vineyards, orchards, cereals,nuts, etc.); Pesticide treatments in greenhouses
and nurseries; Disinfestation
Construction, building and renovation:
• Waste Management: Refuse handling and disposal.
• Wood working: Glueing
• Working with fibreglass and minerals: Blending/mixing and tile laying; Spraying.
• Maintenance: Disinfection and cleaning.
• Painting: Gardening Spray painting / coating with latex paint.
4.2 LIMITATIONS
a) Do not use in atmospheres immediately dangerous to life or health.
b) Do not use against gas and vapors if the respirator is fitted only with dust filters.
c) Do not wear for protection against gases, vapours, carbon monoxide, natural gas and
fumigants.
d) Do not use for protection against fire smoke.
e) Do not use in closed environments (tanks, silos etc.).
f) Do not use in atmospheres containing less than 17% oxygen.
g) Do not use in explosive atmospheres.
h) Do not use for protection against harmful dust where the concentration in the atmosphere
exceeds 500 times the TLV (UNI10720)
i) Do not use in environments with concentrations lower than 500 times the TLV when said
concentrations produce situations immediately dangerous to life and health.
5.
USE INSTRUCTIONS
5.1
BATTERY CHARGING:
5.1.1 LI-870 BATTERIES:
Charging of the rechargeable Lithium battery must be done exclusively with the
KASCO LI-02 battery charger (see use instructions packed with the respirator).
Recharge time: 3 hours
RECHARGE THE BATTERY AFTER EACH USE.
5.1.2 LITHIUM BATTERIES LI-3:
Charging of rechargeable lithium batteries 3S1P must be carried out with Kasco LI-3
charger only (see instructions).
Recharge time: 3 hours
5.1.3 NM-300/8 BATTERY:
The built-in battery can be recharged with the KASCO Z15/220 battery charger .
The built-in battery recharge can be done in the following ways:
a) with blower Off and tractor not running (about 14 hours to charge)
2 years
b) with tractor running and blower unit switched either ON or OFF indifferently
>8
or 300
c) with Z15/220 battery charger and blower unit in the OFF position. Recharge time:
cycles
about 14 hours
2 years
STORE THE BATTERIES ALMOST COMPLETELY DISCHARGED WITH BLOWER
>8
or 300
UNIT SWITCHED OFF AND THE CORD UNPLUGGED FROM THE BLOWER.
cycles
5.2 PREPARING THE RESPIRATOR:
5.2.1 T8 / T8X BLOWER UNITS:
N.A
N.A
a)
Slip the belt through the battery and blower hook .
b)
Connect the battery to the blower with the cord and screw tight to make contact.
2 years
c)
Make sure that the unit is ON and running properly.
>8
or 300
d)
Make sure that the filter gasket is properly inserted into the filter housing.
cycles
e)
Before using the filter for the first time check the expiry date to make sure the filters
have not expired; make sure that seals have not been broken and that the filters are
N.A
N.A
the correct ones for the respirator model in use.
f)
Remove covers from the filter and screw the EN148-1 threaded connection end onto
2 years
the chosen respirator. Read the filter use instructions.
> 2
or 300
 
5.2.2 T9R AND T9 WITH SP9 CORD:
cycles
a)
Plug the proper cord into the socket located on the tractor dashboard and connect to
the blower .
2 years
b)
Make sure that the blower unit is running properly.
>4
or 300
c)
Make sure the filter gasket is properly inserted in the housing.
cycles
5.2.3 FILTERS:
2 years
a)
Before using the filter for the first time check the expiry date to make sure the filters
>4
or 300
have not expired; check that the seals are intact and that the filters are the proper
cycles
ones for the respirator model in use. Take care not to confuse the markings on the
filters with those of other standards which classify this RPD according to EN
12941:98+A1/03+A2/08.
b)
Remove covers and/or seals and screw the EN148-1 threaded end of the filter onto
the respirator. Read the filter use instructions.
5.2.4 HELMET SET-UP:
a)
Remove protective film from visor. The film was applied to preserve facepiece
transparency till the moment of use.
b)
Fit the helmet steadily on head by adjusting harness/head band fit.
c)
Connect the breathing tube to the helmet (where applicable).
d)
Open the visor if it is the flip-up type.
5.3 DONNING INSTRUCTIONS:
a)
Don helmet in a fresh air environment only.
b)
Fit belt, with blower unit and filters already attached on the left and battery on the
right, around waist.
c)
Put helmet on and tighten collar drawstring around neck by pressing the button. The
drawstring should be pulled as close as possible round neck to ensure maximum
closure but it should at all times feel comfortable and not restrict breathing. Any
garment used to protect the worker's neck should adhere as much as possible
around the neck in order to avoid possible folds of the fabric which could interfere
with the proper closure.
IST-USO-0906004
Rev. N. 3 del 31/01/2020
IDP107
Pag.6 di 23
Painting and surface coating.