Setting up and connecting the refrigerator
7.1
Installing the refrigerator
In continuous operation, the air humidity may not exceed 90%.
Set up the refrigerator in a dry, sheltered place. Avoid placing it near heat sources
such as radiators, gas ovens or hot water pipes. Do not let it stand in direct, strong
sunlight.
The refrigerator must be positioned so that heated air can dissipate easily. Therefore
make sure there is adequate ventilation (fig. 4, page 4).
No. in fig. 4,
Explanation
page 4
1
Hot waste air
2
Cold intake air
3
Condenser
4
With decorative panel 50 mm space at the top!
I
NOTE
The cooling unit is detachable and can be installed up to 1.5 metres
away from the refrigerator if there is limited space.
7.2
Releasing the lock
The refrigerator has a locking mechanism (fig. 5 1, page 5) which is also used to
protect it during transport. The following settings are possible:
A
NOTICE!
Only adjust the locking mechanism when the door is open. If you use it
with the door closed, you will damage the refrigerator.
•
Normal lock (turn wheel clockwise to the end stop): the door is locked and
secured.
To open the door, lift the handle up and open the door.
•
Vent (turn wheel anti-clockwise to the end stop): The door is slightly open and
fixed in place.
Use this position, if you are not going to use the refrigerator for a long time.
14
CRP40
EN