Herunterladen Inhalt Inhalt Diese Seite drucken

Space Requirement For Outdoor Unit; Outdoor Unit Installation; Install The Drain Pipe For Outdoor Unit - Carrier 42QTD009DS Serie Installationshandbuch

Vorschau ausblenden Andere Handbücher für 42QTD009DS Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 21

3. OUTDOOR UNIT INSTALLATION

3.3 SPACE REQUIREMENT FOR OUTDOOR UNIT

Single Unit Installation
(Wall or obstacle)
Air inlet
>30cm
N
Air inlet
M
Parallel connect the two units or above
>30
>60
>200
3.4 INSTALL THE OUTDOOR UNIT
Before installation, check strength and horizontality of the base so that abnormal sound does not
generate.
Fix the base firmly with anchor bolts (M10) to prevent it from collapsing.
Install the foundation and vibration-proof rubbers to directly support the bottom surface of the fixing
leg that is in contact with the bottom plate of the outdoor unit.
Mortar Hole (Φ100mm x Depth 150mm)

3.5 INSTALL THE DRAIN PIPE FOR OUTDOOR UNIT

Connect the drain outlet with an extension drain hose
Fit the gasket onto drain outlet.
Insert the drain outlet into the base pan hole of outdoor unit, and rotate 90 degree to securely assemble
them.
GB-11
7
Maintain channel
>60cm
P
Air outlet
unit:cm
≥100mm
Drain Outlet
Parallel connect the front with rear sides.
>200
>50
Outdoor unit
Vibration-proof rubber
Anchor bolt (M10)
Drainage (Wide 100mm x Depth 150mm)
Base pan hole
of outdoor unit
Gasket
Drain hose
(Field supply)
Fix with bolt
unit:cm
>300
>300
>30

Werbung

Inhaltsverzeichnis