Herunterladen Inhalt Inhalt Diese Seite drucken

IKEA datid HGA4K Gebrauchsanweisung Seite 14

Vorschau ausblenden Andere Handbücher für datid HGA4K:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ENGLISH
- loosen screw to increase the flame height
(+).
The adjustment must be performed with the
tap in minimum gas setting position (small
flame ) .
- The primary air of the burners does not
need to be adjusted.
- At this stage, light up the burners and
turn the knobs from max position
to minimum position
stability.
Upon completion of adjustment, reseal
the work surface using sealing wax or an
equivalent material.
FR
REFERENCE TO LOCAL
REGULATIONS
The installation and maintenance of the
appliance must be carried out by a qualified
skilled technician in accordance with the
regulations in force, and in particular:
• Decree of 2 August 1977
Technical and Safety Rules applicable to fuel
gas and liquefied hydrocarbon installations
located within residential buildings and
outbuildings.
• Standard DTU P 45 - 204
Gas installations (formerly DTU no. 61-1 -
Gas installations April 1982 + supplement
no. 1 of July 1984).
• Departmental Health Regulations
For appliances connected to the mains
electricity supply.
• Standard NF C 15-100
Low-voltage electrical installations -
Standards.
to check flame
BE
REFERENCE TO LOCAL
REGULATIONS
The appliance is supplied with a 1/2"
threaded conical end to be connected to
the gas supply (according to ISO regulations
ISO 7/1 RP 1/2).
The connection must be effected in
accordance with standard NBN D 51-003
using rigid piping or in accordance with
specifications sheet A.R.G.B./03 using
flexible tubing.
The appliance must be installed complete
with an AGB-approved stop valve.
14

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis