3.5 Type label

CBU 140-25A-043
230 V ~1
50 Hz
H
:43 m Q
max
FO002115
1
Series
2
Frequency
3
Serial number
4
Power output
5
max. feed rate
Key for the serial number
Calendar
2009 2010 2011 2012 2013
year
1st half-year
S-U
2nd half-year
S-V
3.6 Version
Plug-in ready compact booster unit, consisting of:
Self-priming multi-stage centrifugal pump
Monitoring and control unit for the centrifugal pump
System control
Inlet tank with integrated drinking water inlet via
mechanical float valve and free outlet according to EN
1717
fastening set for wall mounting, consisting of screws,
wall plugs and mounting bracket
Flexible expansion joint connection PN10 with
DVGW-/TÜV approval and 10-year guarantee for the
pressure side as well as the drinking water connection
(length approx. 30/50 cm)
Membrane pressure expansion vessel
Installation manual with mounting template
3.7 Overview
In an angular tank designed for wall mounting there is a multi-
stage high-pressure pump. The high-pressure pump is
connected via bent tube to an inlet, which leads to the supply
tank.
S - B
3,7 A
800 W IP44
3
:4,1 m
/h
max
1
Rated voltage
2
max. power input
3
max. pumping head
4
Protection class
S-W
S-Y
S-A
S-C
S-X
S-Z
S-B
S-D
GB
Fig. 1 CBU140 Structure
1
Pump control
2
Pump
3
Inlet tank
4
Drinking water
connection

3.8 Intended use

The compact booster unit may only be operated in such areas
as described in the other applicable documents.
Non-intended operation of the compact booster unit can
result in danger to persons, systems, the surroundings and
the environment.
Operate the compact booster unit only if it is in perfect
working condition.
Do not operate the compact booster unit if it is only
partially assembled.
The compact booster unit may only be used to pump
the medium as described in the documentation of the
respective version.
Never operate the compact booster unit without pump
medium.
Observe the values for minimum pumping rates
(avoiding damage because of overheating, storage
damage, ...).
Observe the values for maximum pumping rates (to
avoid damage due to overheating, floating ring seal
damage, cavitation damage, storage damage, ...).
Do not throttle the input of the compact booster unit (to
avoid cavitation damage).
Other modes of operations, if not mentioned in the
documentation, have to be coordinated with the
manufacturer.
8
5
Pressure delivery
6
Tank
7
Vent valve
MU1H-1377GE23 R0320