Assembly; Installation Site - resideo Braukmann CBU140 Einbauanleitung

Einzelpumpen-sicherheitstrennstation
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

1.
To unpack, cut the packaging straps.
2.
Take the accessories and the extra padding out of the
box.
3.
Lift the box upwards.
– The system stands alone on the wooden pallet.
4.
Check the contents of the package for completeness.
5.
Check the system for transport damage.
6.
Select the appropriate means of transport.
7.
Transporting the system to the installation site.
6

Assembly

6.1 General safety instructions
DANGER!
Danger of injury from electric voltage.
High shock currents and burns from direct and
indirect contact with live parts.
Turn off the power supply before assembling the
compact booster unit and secure it from being
turned on.
Faulty mains connection
Damage to the electricity network, short circuit!
The electrical system must conform with the
installation regulations according to VDE 100 (i.e.
grounded electrical sockets).
The electrical network must be equipped with a
residual current device for max. 30mA.
Non- or erroneously-connected cables
Malfunctions, which endanger the safety of
operating personnel.
Work on electrical equipment may only be
performed by specialist electric technicians.
Improperly connected wiring and lines (e.g. too small
bend radius)
Smouldering and fires from cables.
Work on electrical equipment may only be
performed by specialist electric technicians.
Live cable ends and components
Make sure the protective earth system is connected
throughout.
WARNING!
The compact booster unit is not designed for
operation outside.
Temperature, light and moisture influences can
lead to malfunctions and damage to devices.
Do not use the compact booster unit outside.
Danger through improper installation
Personal and property damage!
Performance of tasks only by qualified personnel (see
section 1.10.1 Operating personnel).
GB
CAUTION!
Damaged or improperly installed compact booster
unit.
Malfunctions
Do not damage the compact booster unit and only
install it if it is clean and fully functional.
Install the compact booster unit according to the
described instructions.
Install free of voltage and of bending moments.
Connecting cable overly bent
Defective system due to improper load on the
system
Reduction of service life!
Install connecting cable with zero potential. No load
is allowed to be put on either the connections or the
system.
Drinking water inlet of max. 4bar exceeded
Defective system due to improper load
Install pressure reducing valve ahead of the system
to ensure that not more than 4bar prepressure is
fed from the drinking water network.
6.2 Installation according to EN1717
Accomodate the compact booster unit in a technical centre or
in a frost-free, well ventilated, lockable room that is not used
for anything else. Hazardous gases should never enter the
installation room. A sufficiently dimensioned dewatering
connection (drain connection or similar) is required (observe
EN 12056).
Usable volume tank
13 l
Table 6: Usable volume/dewatering capacity
Do not operate the compact booster unit near living
rooms and
bedrooms.
6.3 Inspection before assembly
Check the following points prior to installation:
According to specifications on the type label, the
system is suitable for the electric supply network.
The medium to be pumped corresponds to the
permissible pumping media
The above-mentioned safety instructions have been
observed.
The installation room is dry, frost-free and well-
ventilated.

6.3.1 Installation site

Ideally select an outer wall for mounting.
The wall must be able to take 4 wall plugs Ø 10 mm
and carry the weight of the system (approx. 35 kg
when filled with water).
10
Dewatering capacity
5,4 m3/h
MU1H-1377GE23 R0320