1.1 CLEANING

Now that our cabinet is correctly installed, we must proceed to cleaning it:
The first cleaning must be carried out with water and neutral detergent. Once clean and dry, insert
the accessories in the appropriate places, as you prefer.
We recommend cleaning the outside of the unit daily with a damp cloth and following the direction
of the stainless steel's polished finish. Abrasive substances or those containing chlorine must not be
used. Rinse with clean water, avoiding direct water jets.
1.2

GENERAL CONNECTION

Before connecting the cabinet to the socket, check that the network voltage and frequency
correspond to those indicated on the appliance's nameplate.
It is essential that the electrical installation where the cabinet is going to be connected
has an EARTHING SOCKET, in addition to the appropriate magneto-thermal switch and
differential protection (we recommend 30 mA)
Check that the section of the electricity socket is appropriate for the consumption it is going to
withstand. It must be a Schuko type socket, as your cabinet's cable is this type (also called F type
and in the EEC 7/4"), with a 4.8 mm terminal and earthing socket.
For your safety, it is prohibited to lengthen this power cable. Do not insert any elements through the
fan guard or refrigerator equipment area grilles. The place where the unit is going to be installed
must be perfectly levelled. In the fish cabinets, the cabinet's drainpipe must be connected to the
general drainage system. This will be carried out according to local regulations.
In the start-up, ensure that there are no sources of heat nearby. For the perfect operation of the
components making up the refrigerator system, it is extremely important that the air intakes, both
from the fan situated inside the cabinet and the air access to the condenser not be blocked.
Do not install the cabinet outdoors.
To adjust the electrical protection, see plate number plate.
Furthermore, the cabinets, on order, are delivered with H type (United Kingdom).

MATRICULATION PLATE

1.3
MATRICULATION PLATE
Explanation of the matriculation plate that comes with your cabinet
NUMBER
DESCRIPTION
1
CONSTRUCTION COMPANY
2
MODEL
3
SERIES NO.
4
REFRIGERATION POWER WATTS
5
WORKING VOLTAGE
6
FREQUENCY
7
CURRENT INTENSITY
8
TYPE OF COOLANT GAS
9
GRAMS OF COOLANT GAS
10
CLIMATIC CLASS
11
STANDARD