Herunterladen Inhalt Inhalt Diese Seite drucken

Victron energy Battery Monitor BMV-700 Anleitung Seite 31

Vorschau ausblenden Andere Handbücher für Battery Monitor BMV-700:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 123
Parameter
  
  
  
 
 
  
  
  
    
 
   
   
*   
*   
  
  
* BMV-702 and 712 only
Description
The deepest discharge in Ah.
The largest value recorded for Ah
consumed since the last synchronisation.
Average discharge depth
The number of charge cycles. A charge
cycle is counted every time the state-of-
charge drops below 65%, then rises above
90%
The number of full discharges. A full
discharge is counted when the state of
charge reaches 0%.
The cumulative number of Amp hours
drawn from the battery.
The lowest battery voltage.
The highest battery voltage.
The number of days since the last full
charge.
The number of automatic synchronisations
The number of low voltage alarms.
The number of high voltage alarms.
The lowest auxiliary battery voltage.
The highest auxiliary battery voltage.
The total amount of energy drawn from the
battery in (k)Wh
The total amount of energy absorbed by the
batteryin (k)Wh