Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection For The Uk - Miele SM Serie Gebrauchsanweisung

Kabelloser handstaubsauger
Vorschau ausblenden Andere Handbücher für SM Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en
Electrical connection for
the UK
All electrical work should be carried out
by a suitably qualified and competent
person in strict accordance with current
national and local safety regulations (BS
7671 in the UK). The voltage and fre-
quency are given on the data plate loc-
ated underneath the vacuum cleaner.
Please ensure that these match the
household mains supply. The fuse rat-
ing is quoted on the plug. The appli-
ance is supplied with a cable and moul-
ded plug ready for connection to a
230-240 V/50 Hz a.c. single phase sup-
ply.
Non-rewireable plugs BS 1363
The fuse cover must be re-fitted when
changing the fuse, and if the fuse cover
is lost the plug must not be used until a
suitable replacement is obtained. The
colour of the correct replacement cover
is that of the coloured insert in the base
of the plug, or the colour that is em-
bossed in words on the base of the
plug, (as applicable to the design of
plug fitted). Replacement fuses should
be ASTA approved to BS1362 and have
the correct rating. Replacement fuses
and fuse covers may be purchased
from your local electrical supplier.
59