Balluff BES M12EH1-L01C40B-S04G-L04 Anleitung Seite 156

Io-link configuration
Vorschau ausblenden Andere Handbücher für BES M12EH1-L01C40B-S04G-L04:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BES M12EH1-L01C40B-S04G-L04 / BES M18EH1-L01C80B-S04G-L04
Inductive sensors
5
Secondary Device Functions (continued)
5.9.5
System Commands
Command Value Device Action
0x81 (129)
Application Reset – Resets the
Voltage monitoring detection time
duration with ISDU-index 0x58
subindex 2 to the default value 0.
0x82 (130)
Reset Factory Settings – Resets the
Voltage monitoring detection time
duration with ISDU-index 0x58
subindex 2 to the default value 0.
0xA5 (165)
Maintenance Reset – Resets the
Voltage monitoring detection time
duration with ISDU-index 0x58
subindex 2 to the default value 0.
Tab. 5-42: Voltage and current monitoring – System Commands
For an overview of all System Commands, see section 3.5
on page 21.
5.9.6
Events
Event Code
Event Type
0x5110
Warning
(20752)
0x5111
Warning
(20753)
0x8D0B
Warning
(36107)
0x8D0D
Warning
(36109)
0x8D15
Warning
(36117)
Tab. 5-43: Voltage and current monitoring – Events
62
english
Description
Primary supply voltage exceeded
► Check for deviations in the supply.
Primary supply voltage below minimum value
► Check for deviations in the supply.
Overload or short circuit at pin 2
► Check wiring.
Incorrect load/cable breakage
► Check wiring or connected devices.
Overload at pin 2
► Check wiring.
Device Status
2 – Out-of-Specification
2 – Out-of-Specification
2 – Out-of-Specification
2 – Out-of-Specification
2 – Out-of-Specification