BES M12EH1-L01C40B-S04G-L04 / BES M18EH1-L01C80B-S04G-L04
Inductive sensors
3
Overview of IO-Link Data and Functions (continued)
Name
Index
Teach-In Channel
0x003A
Teach-In Status
0x003B
SSC 1 Parameter
0x003C
Setpoint 1
Setpoint 2
SSC 1 Configuration
0x003D
Switchpoint Logic
Switchpoint Mode
Switchpoint Hysteresis
SSC 2 Parameter
0x003E
SSC 2 Configuration
0x003F
Transducer Signal
0x01B2
(434)
Data storage possible for SSC parameters. Switching interval can change after sensor change.
1)
Low Signal Quality
0x00CE
Threshold
(206)
Current Signal Quality
0x00CF
(207)
Signal Quality Bad
0x00CF
(207)
External Signal
0x0421
Blanking
(1057)
www.balluff.com
Sub-
Access
index
Switching profiles (LSSC)
0
RW
(58)
0
RO
(59)
0
RW
(60)
1
RW
2
RW
0
RW
(61)
1
RW
2
RW
3
RW
0,1,2,3
RW
(62)
0,1,2,3
RW
(64)
0
RO
Signal Quality
0
R/W
1
R
2
R
External Signal Blanking
0
R/W
Length
Data Type
Storage
8 bits
UIntT8
8 bits
UIntT8
64 bits
RecordT
32 bits
IntT32
32 bits
IntT32
32 bits
RecordT
8 bits
UIntT8
8 bits
UIntT8
16 bits
IntT16
64 bits
RecordT
32 bits
RecordT
16 bits
IntT16
1 byte
UINT8
1 byte
UINT8
1 bit
BOOL
1 byte
ENUM
Data
Default
No
0x00
No
–
Yes
–
1)
No
0x00000064 (100)
No
0x7FFF FFFC
(deactivated)
Yes
–
No
0x00
No
0x01
No
0x19 (25)
Yes
–
1)
Yes
–
No
–
Yes
0
No
255
No
0
No
0
english
13