Parameter Matrix
Konfigurationsübersicht Parameter- Menü
TW
Fritteuse
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Text
Sound-Level
Standby-Time
Standby-Temperatur
Standby-Temperatur
Power-On Temperaturdifferenz
Level Clean-Temperatur
Oillimit Hub OFF
Auto. Filtrierung
Auto. Entleerung (Time 1)
Auto. Zirkulation (Time 2)
Auto. Befüllung (Time 3)
Salinity-Alarm (Low)
Salinity-Alarm (High)
Salinity-Alarm (Time)
Salinity-Alarm (Sound)
Relais-Time
Trockengang
Demo-Mode-Time
Min. Wert
0 = Off
Off / 5 min.
30°C
30°C
10°C
30°C
Off / TPM 10
Off
5 sec.
5 sec.
5 sec.
1‰
1‰
1 sec.
Off
2 sec.
Off
Off / 20 sec.
w w w . g a s t r o f r i t . c h
10
Max.
Default
10
1
120 min.
45 min.
80°C
50°C
150°C
130°C
80°C
15°C
170°C
150°C
TPM =40
TPM =5%
On
Off
500 sec.
180 sec.
500 sec.
180 sec.
500 sec.
180 sec.
30‰
8‰
30‰
12‰
60 sec.
10 sec.
On
On
60 sec.
20 sec.
On
On
240 sec.
Off
© Switzerland Gastrofrit AG