Switching off
To turn off the appliance, turn the
Temperature regulator to the "O" position.
The pilot light will switch off and you will
hear the buzzer.
Temperature regulation
The temperature is regulated automatically.
A medium setting is generally the
most suitable. However, the
exact setting should be chosen
keeping in mind that the
temperature inside the appliance
depends on:
• room temperature,
• how often the door is opened,
• the quantity of food stored,
• the location of the appliance.
1. Turn the Temperature regulator toward
lower settings to obtain the minimum
coldness.
2. Turn the Temperature regulator toward
higher settings to obtain the maximum
coldness.
Caution! If the ambient
temperature is high or the
appliance is fully loaded, and the
appliance is set to the lowest
temperatures, it may run
continuously causing frost to form
on the rear wall. In this case the
dial must be set to a higher
temperature to allow automatic
defrosting and therefore reduced
energy consumption.
Fast Freezing function
1. Press the Fast Freezing switch to
activate the Fast Freezing function.
Downloaded from
www.Manualslib.com
manuals search engine
The Fast Freezing light will light up.
2. Press the Fast Freezing switch to
deactivate the function at any time.
The Fast Freezing light will switch off.
This function stops automatically
after 52 hours.
High temperature alarm
An increase in the temperature in a
compartment (for example due to an power
failure) is indicated by flashing of the Alarm
light.
When normal conditions are restored the
Alarm light will switch off automatically.
Acoustic alarm
An acoustic alarm will sound when the
temperature inside the freezer has risen to
a point where the safe storage of frozen
food is no longer ensured.
When normal conditions are restored, the
acoustic alarm will stop.
In any case, press the Alarm
reset switch to deactivate the
acoustic alarm.
Door open alarm
An acoustic alarm will sound when the door
is left open for around 80 seconds.
When normal conditions are restored (door
closed), the acoustic alarm will stop.
In any case, press the Alarm reset switch to
deactivate the acoustic alarm.