EXTENDED MENU 1

The control unit is supplied by the manufacturer with the
possibility of selecting only the main menu functions.
To enable the functions listed in extended menu 1, proceed as
follows: press the SET button and hold for 5 seconds, after
which the T. PAUSA LED and RIT. ANTE LED will flash
alternately. You have 30 seconds to select the functions of
Extended Menu 1 using the SEL and SET buttons. After
another 30 seconds, the control unit returns to the main menu.
----------------------
EXTENDED MENU 1
Reference LED
LED Off
A) AUT / P-P
PGM remote = OFF
B) CODE
Test Photocell = ON
C) CODE PED.
Mant. Pressure = OFF
D) INB.CMD.AP Water Hammer = OFF
E) T. MOT.
Closing Hammer = OFF
F) T.MOT.PED.
Safety Device 2
G) T. PAUSA
Alternate ON/OFF flashing light
H) RIT. ANTE
Flashing beacon ON/OFF in alternation
A) AUT / P-P
( Remote programming of radio control ):
The control unit allows the transmission code to be
programmed, without using the SEL button directly on the
control unit, but remotely.
The remote transmission code can be programmed as follows:
continuously sending a previously-memorised radio control
code for more than 10 seconds. At this point the control unit
switches to programming mode, as described above for the
CODE LED in the main menu.
The control unit is supplied by the manufacturer with the
remote transmission code programming function disabled. If
you wish to enable the function, proceed as follows: check that
Extended Menu 1 is enabled (RIT. ANTE LED and T. PAUSA
LED start flashing alternately, with the SEL key positioned on
the flashing of AUT/ P-P LED then press the SET key, the
AUT/P-P LED will simultaneously stays on steadily and
programming is completed. Repeat the procedure to restore
the previous configuration.
B) CODE ( Test Photocell ) :
The control unit is supplied by the manufacturer with photocell
Test programming enabled (in accordance with Standard EN
12453). If you wish to disable the function proceed as follows:
check that Extended Menu 1 is enabled (T. PAUSA and RIT.
ANTE LEDs flashing alternatively), with the SEL key position on
the flashing of CODE LED then press the SET key, the CODE
LED will simultaneously stay on steady and programming is
completed. Accordingly, the photocell test will not be carried
out, therefore even if not connected (if unused, DS1 and DS2
inputs must be jumped), the control unit is enabled for
operation. Repeat the procedure to restore the previous
configuration.
C) CODE PED ( Hydraulic Motors Maintenance Pressure ) :
The control unit is supplied by the manufacturer with the
hydraulic motors maintenance pressure function disabled. If
you wish to enable the function, proceed as follows: make sure
that you have enabled Extended Menu 1 (T. PAUSA LED and
RIT. ANTE LED start flashing alternately), with the SEL key
position on the flashing of CODE PED LED then press the SET
key, the PED CODE LED will simultaneously stay on steady
and programming is completed. Accordingly the control unit will
send a closing command every 2 hours to the motor for 2
seconds. Repeat the procedure to restore the previous
configuration.
D) CODE PED. ( Water Hammer ) :
The control unit is supplied by the manufacturer with Water
Hammer disabled. If you wish to enable the Water Hammer
function, proceed as follows: check that Extended Menu 1 is
enabled (RIT. ANTE LED and T. PAUSA LED start flashing
------------------
LED On
PGM remote = ON
Test Photocell= OFF
Mant. Pressure = ON
Water Hammer = ON
Closing Hammer = ON
Block Input
alternately), with the SEL key position on the flashing of
INB.CMD.AP LED then press the SET key, the INB.CMD.AP
LED
will
simultaneously
programming is completed. If you wish to enable the Water
Hammer function to the power set through the "POWER"
Trimmer, repeat the operation described above, pressing the
SEL button twice instead of once (making the INB.CMD.AP.
LED flash rapidly). Repeat the operation to restore the initial
configuration.
Accordingly, we can facilitate the release of the gate and
therefore allow the proper execution of the opening phase. In
fact, the control unit, before starting the opening phase sends a
closing command for 2 seconds with power relative to the
choice selected.
E) T. MOT. ( Closing Hammer ) :
The control unit is supplied by the manufacturer with the
Closing Hammer Function disabled. If you wish to enable the
Closing Hammer function, proceed as follows: make sure that
you have enabled Extended Menu 1 (RIT. ANTE LED and T.
PAUSA LED start flashing alternately), with the SEL key
position on the flashing of T.MOT. LED then press the SET key,
the T.MOT. LED will simultaneously switch on permanently and
programming is completed. If you wish to enable the Closing
Hammer function to the power set through the "POWER"
Trimmer, repeat the operation described above, pressing the
SEL button twice instead of once (making the T.MOT. LED
flash rapidly). Repeat the operation to restore the initial
configuration.
Accordingly the control unit, if functioning with Deceleration
during closing, will reach (after having completed the
deceleration closing phase) a time of 1 second with power
relative to the choice selected in order to overcome the gate
installed.
F) T. MOT. LED ( Safety device 2 / Block ) :
The control unit is supplied by the manufacturer with the Block
input function disabled. If you wish to enable the function,
proceed as follows: make sure that you have enabled Extended
Menu 1 (T. PAUSA LED and RIT. ANTE LED start flashing
alternately), by using the SEL key select the flashing T. MOT.
PED. LED and press the SET button: T. MOT. PED. LED stays
steadily lit and programming is complete.
Accordingly the control unit, changes the function provided for
Safety Device 2 input ( CN2 no. 9-10 ) in safety block input
with the following function: the intervention in any function
phase of the control unit triggers the immediate stop of motion.
A further motion command will be valid as long as the block
input has been deactivated and, in any case, will carry out the
automatism closing phase with a pre-flashing interval of 5 sec.
EXTENDED MENU 2
The control unit is supplied by the manufacturer with the
possibility of directly selecting the main menu functions only.
To enable the functions listed in Extended Menu 2, proceed as
follows: open Extended Menu 1 (as instructed in the respective
section), then press and hold the SET key for 5 seconds, the T.
PAUSA LED and RIT. ANTE LED will flash simultaneously,
accordingly, you have 30 seconds to select the functions of
Extended Menu 2 using the SEL and SET buttons. After
another 30 seconds, the control unit returns to the main menu.
----------------------
EXTENDED MENU 2
Reference LED
LED Off
A) AUT / P-P
Follow Me = OFF
B) CODE
PreFlash. and Cort. L=OFF PreFlash. or Cort. L. =ON
C) CODE PED.
Pause Lamp. = OFF
D) INB.CMD.AP SOFT START = OFF
E) T. MOT.
El. Gate CMD PED = OFF
F) T.MOT.PED.
PUL=PUL - PED=PED
G) T. PAUSA
Flashing beacon ON/OFF simultaneous
H) RIT. ANTE
Flashing beacon ON/OFF in simultaneous
switch
on
permanently
-----------------
LED On
Follow Me = ON
Pause Lamp. = ON
SOFT START = ON
El. Gate CMD PED = ON
PUL=AP - PED=CH