The SET key: this programs the information according to the
type of function previously selected with the SEL button.
IMPORTANT: The function of the SET key can be replaced with
the radio control, if programmed previously (CODE led on).
MAIN MENU
The control unit is provided by the manufacturer with the
possibility of selecting a number of important functions.
---------------------- MAIN MENU -----------------
LED Reference
LED off
1) AUT / P-P
Automatic
2) CODE
No code
3) CODE PED.
No code
4) INB.CMD.AP
Disabled
5) T. MOT.
30 sec. motor time
6) T.MOT.PED.
Mot. Time Ped. 10 sec.
7) T. PAUSA
No auto close
8) RIT. ANTE
No gate delay.
1) AUTOMATIC / STEP BY STEP:
The default settings of the control unit have " Automatic "
operating logic enabled (AUT/P-P LED off), if you want to
enable the operating logic "Step by Step" (AUT/ P-P LED on), it
is necessary to enable it; use the SEL key to move to the
flashing AUT/P-P LED then press the SET key. AUT/P-P will
light up steadily. Repeat the procedure to restore the previous
configuration.
2) CODE: (Radio control code)
The control unit can store up to 150 radio controls with different
fixed or rolling codes.
Programming.
The transmission code is programmed in the following way:
using the SEL key to move to the flashing CODE LED, at the
same time send the pre-selected code from the radio control
you wish to use; when the CODE LED stays on steadily,
programming is finished. If all 150 available codes have been
memorised, by repeating the programming operation, all
programming LEDs will start to flash, indicating that it is not
possible to memorise any more codes.
Deletion.
All the stored codes are deleted as follows: press the SEL
button until the CODE LED** flashes, then press the SET
button and the CODE LED turns off and the codes are deleted.
3) CODE PED:(Code for the radio control Ped. / Anta S.)
The programming and deleting procedure is the same as the
one illustrated above except that the selected LED should be
for PEDESTRIAN CODE.
4) INB. CMD. AP: (Command inhibition during opening and
pause time, if entered)
The command inhibition function during opening and pause
time, if entered, is used when automation includes a loop
detector. During the opening or pause phase the control unit
does not receive the commands sent by the loop detector with
every passage.
The default settings of the control unit have disabled command
inhibition during opening and pause time. If it is necessary to
enable it, do the following: use the SEL key to move to the
flashing INB.CMD.AP LED then press the SET key. The
INB.CMD.AP LED will light up steadily. Repeat the procedure to
restore the previous configuration.
5) T. MOT and DECELERATION:
time of max 4 minutes)
The control unit is supplied by the manufacturer with a default
motor operation time of 30 seconds, without deceleration.
LED On
Step by Step
Code entered
Code entered
Enabled
Programmed time
Programmed time
With auto close
Programmed time
(Programming a motor operation
If it is necessary to modify the operating time of the motors,
programming must be carried out when the gate is closed, as
follows: use the SEL key to move to the flashing T.MOT LED.
then press the SET key briefly. Motor 1 will start the opening
cycle; in correspondence with the point desired to start
deceleration press the SET key again: the T. MOT. LED. will
start flashing more slowly and Motor 1 will decelerate; when the
desired position is reached, press the SET key to complete the
opening cycle. The T. MOT LED will now start flashing normally
again and Motor 2 will begin its opening cycle: repeat the
operations to program the work time for Motor 2,
programming the opening times for the motors, Motor 2 will
start its closing cycle: repeat the same instructions as above for
programming the closing cycle of Motor 2 and then for Motor 1.
If you do not want the control unit to decelerate, when the
opening and closing phase is finished, press the SET key twice
during programming, instead of just once.
During programming it is possible to use the radio control key
located on the control unit, instead of the SET key, only if
previously memorised.
6) T. MOT. PED:
(Programming a pedestrian operating time of 4
minutes max.)
The control unit is factory supplied with a predefined
(Pedestrian) Motor 1 operating time of 10 sec. without
deceleration.
If it is necessary to modify the pedestrian operating time,
programming must be carried out when the gate is closed, as
follows: use the SEL key to move to the flashing T.MOT PED.
LED, then press the SET key briefly. Motor 1 will start the
opening cycle; in correspondence with the point desired to
start deceleration, press the SET key again: the T. MOT. PED.
LED will start flashing more slowly and Motor 1 will decelerate;
when the desired position is reached, press the SET key to
complete the opening cycle. At this point the T. MOT PED. LED
will start flashing at its standard pace again and the Motor 1 will
begin the closing phase; repeat the above operations for the
closing phase. If you do not want the control unit to decelerate,
when the opening and closing phase is finished, press the SET
key twice during programming, instead of just once.
During programming it is possible to use the radio control key
located on the control unit, instead of the SET key, only if
previously memorised.
7) T. PAUSA:
(Automatic closing time programming max. 4 minutes)
The control unit is factory supplied without automatic closing. If
you wish to enable automatic closing, proceed as follows: using
the SEL key to move to the flashing T. PAUSA LED, press the
SET key briefly, then wait for the amount of time you wish to set
for automatic closing; briefly press the SET key again, and in
that moment the automatic closing time will be stored and the
T. PAUSA LED will stay on steady. If you wish to restore the
initial condition ( without automatic closing ), move to the
flashing T. PAUSA LED, then press the SET key twice within 2
seconds; the LED will shut off and the operation will be
complete.
During programming the radio control key of the control unit
can be used instead of the SET key, if stored previously.
8) T. RIT. ANTE :
(Programming door delay of 15 sec. Max.)
The control unit is supplied by the manufacturer without gate
delay during opening and closing. If it is necessary to enter a
gate delay time, programming must be carried out when the
gate is closed, as follows: use the SEL key to move to the
flashing RIT. ANTE LED, press the SET key, wait for desired
interval of time, then press the SET key again: the gate delay
time opening will be stored, at 2 seconds, of the delay time of
the door closing for the time programmed and the RIT. ANTE
LED is steady.
To restore the initial configuration (without door delay), go to
the RIT. ANTE LED when flashing then press the SET key
twice within 2 seconds, the LED goes off and the operation is
completed.