TECHNICAL DATA:

- Power supply 230 Vac 50-60Hz 1600W max.
- Flashing light output
- Motor outputs
- Electric lock output
- Power supply to photocells
- Safety devices and controls in BT: 24 Vdc
- Working temperature
- Radio receiver
- Op. transmitters
-TX max codes in memory
- Board dimensions
- Container dimensions
- Protection rating
TERMINAL BOARD CONNECTIONS:
CN1 :
1 : 230 Vac line input (Phase).
2 : 230 Vac line input (Neutral)
3 : 230 Vac Flashing light Output (Neutral).
4 : 230 Vac Flashing light Output (Phase).
5 : Motor 1 Output opening.
6 : Motor 1 Output common.
7 : Motor 1 Output closing.
8 : Motor 2 Output opening.
9 : Motor 2 Output common.
10 : Motor 2 Output closing.
CN2 :
1 : Photocell Control and Power Supply ( 24Vac ).
2 : Photocell Control and power supply ( GND ).
3 : Electric lock output 12 Vdc 15 W ( +12V ).
4 : Electric lock output 12 Vdc 15 W ( GND ).
5 : Open-close push button control PUL input (NA).
6 : Common GND input.
7 : Pedestrian push button control PUL PED input (NA).
8 : Safety device DS1 input (NC).
9 : Common GND input.
10 : Safety device DS2 input (NC).
11 : Antenna earth input.
12 : Antenna hot pole input.
OPERATING CHARACTERISTICS:
Automatic Operation:
By using both the radio control ( CODE LED on ) and the low
voltage push button panel ( PUL ) to activate the gate, the
following functioning is obtained:
the first impulse commands the opening mechanism until motor
time expires. The second impulse commands gate closing. If
an impulse is sent before the motor time has expired, the
control unit will reverse motion direction both for opening and
closing.
Step-by-step operation:
By using both the radio control ( CODE LED on ) and the low
voltage push button panel ( PUL ) to activate the gate, the
following functioning is obtained:
the first impulse commands the opening mechanism until the
motor time expires.
The second impulse commands gate
closing. If an impulse is sent before the
motor time has expired, the control unit will stop the motion
during opening and closing phase. An additional control re-
starts motion in the opposite direction.
Automatic closing :
The control unit closes the gate automatically without sending
additional commands.
Selecting this operating mode is described under the
instructions for setting the pause time.
: 230 Vac 500 W max.
: 230 Vac 50/60 Hz. 500 W max.
: 12 Vdc 15 W max.
: 24 Vac 3 W max.
: -10  55 °C
: see model
: 12-18 Bit or Rolling Code
: 150 (CODE or PED CODE)
: 140x125x45 mm.
: 190x140x70 mm.
: IP 56
Pedestrian Passage:
The control unit allows only Motor 1 to be activated using either
the radio control ( CODE PED. LED on) or the push button
panel ( PED ), for the programmed time. ( T.MOT. PED. LED ).
Safety device 1 :
The control unit allows Photocells to be powered and
connected in accordance with directive EN 12453.
If the device trips during opening, it is ignored. If it trips during
closing, gate motion is reversed.
The control unit compulsorily requires the use of photocells,
connected to dedicated inputs, otherwise the unit is not
enabled for operation.
Safety device 2:
The control unit allows Photocells to be powered and
connected in accordance with directive EN 12453.
If the device trips during opening, the gate stops momentarily.
Once freed, the control unit continues the opening phase. If
the device trips during closing, gate motion is reversed.
The control unit compulsorily requires the use of photocells,
connected to dedicated inputs, otherwise the unit is not
enabled for operation.
Adjusting Power and Initial Surge:
The electronic control unit is equipped with a "POWER "
trimmer to adjust motor Power and Speed, fully managed by
the microprocessor. The adjustment can be made within a
range of 50% and 100% of the Maximum Power.
Nevertheless, every movement has an initial surge, powering
the motor for 2 seconds at the maximum power even if motor
power adjustment is enabled.
Attention: You will need to repeat the Motor Time
programming procedure if you wish to adjust the "POWER",
as operation and deceleration times may be affected.
Deceleration:
The motor deceleration function is used on the gates to stop
them from reaching their final position at a high speed in the
opening and closing phases.
The control unit allows deceleration to be programmed for the
desired points (before the gates are completely open or closed)
during Motor Timer programming (see Main menu). It is also
possible to select the motor power to which the deceleration
phase between 6 different levels of power is carried out (see
Extended menu 3). The intermediate level is set during factory
configuration.
Flashing beacon function:
The electronic control unit is equipped with an output for the
management of the flashing beacon 230 Vac. Its function is
conditioned by motor motion and automatic closing which if
activated, enables the flashing beacon even during pause time.
Operation with TIMER:
The control unit can have a timer set up instead of an open-
close ( PUL ) control button.
Example: at 08:00 the timer closes the contact and the control
unit opens the gate. At 18:00 the timer opens the contact and
the control unit closes the gate. During the interval between
08:00 and 18:00, at the end of the opening phase, the control
unit disables the flashing beacon, automatic closing and radio
controls.
PROGRAMMING :
SEL key: selects the type of function to be stored, selection is
indicated by a flashing LED.
Repeatedly press the key to select the desired function. The
selection remains active for 10 seconds, (indicated by the
flashing LED); after 10 seconds, the control unit returns to its
original status.