Herunterladen Inhalt Inhalt Diese Seite drucken

Problem Shooting; Possible Cause - KKT KOLBE DELTA Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für DELTA:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

English
Operating instructions / Users manual COOKER HOODS
Fault
Light on, but motor does not run
Light not on, motor does not run
Oil leaks
Appliance vibrates
Insufficient air extraction
Appliance unstable
fi90520ATL
15. Problem shooting Cooker hoods

Possible cause

Air flap jammed
Faulty capacitor
Motor bearing faulty
Suspicious smell from motor
The following are possible in addition to the above causes
Faulty lamps
No current, supply cable
incorrectly connected
One-way valve leaking
Bottom casing and
telescopic casing transition
leaking
Motor not rigidly mounted
Hood not correctly mounted
Excessive distance
between hood and hob
Excessive draughts from
open doors or windows
Fixing bracket not securely
mounted
Fixing screws not securely
tightened
11
Solution
Rectify jamming
Change capacitor
Change motor
Change motor
Change lamps
Check fuse, connect cable correctly
Rectify leak
Rectify leaks by suitable means
Mount motor correctly
Mount hood securely
Readjust the distance
Close doors and windows
Tighten fixing bracket screws
Tighten fixing screws
GB

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

SinusDiagonalMulti

Inhaltsverzeichnis