REPLACEMENT PART LIST

No.
1
2
3
4
5

TROUBLESHOOTING

SYMPTOM
No heat
Not enough heat
Too much heat
Downloaded from
www.Manualslib.com
Description
Platinum Electric 1500W
Ceiling Recess Kit
Umbrella Mounting Kit
Tube Suspension Kit
Chain Suspension Kit
POSSIBLE CAUSE (S)
1. Improper connection
1. Heater too small for application
2. Heater mounted too high or too far
1. Heater too large for application
2. Heater mount too low or too close
manuals search engine
1. Check connection to power supply
1. Add additional heater(s)
2. Decrease mounting height or distance
1. Replace with smaller heater
2. Increase mounting height or distance
www.bromicheating.com
Bromic Part No.
BH0320001
BH3130001
BH3130002
BH3130003
BH3130004
CORRECTIVE ACTION