Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance Schedule; Correction Of Malfunctions - Bosch GSK 18 V-LI Professional Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für GSK 18 V-LI Professional:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
OBJ_BUCH-1335-005.book Page 14 Tuesday, November 11, 2014 11:28 AM
14 | English

Maintenance Schedule

Clean the magazine 12. Remove any plastic or wood chips
that may accumulate in the magazine during operation.
Measure
Cleaning the magazine 12 and magazine slider 13.
Ensuring that the discharge lock-off 2 functions properly.

Correction of Malfunctions

Problem
The machine is not operative.
The power tool is ready for operation, but no nails are dis-
charged.
Downloaded from
www.Manualslib.com
Clean the power tool in regular intervals using compressed
air.
Explanation
Prevents the jamming of nails.
Promotes your work safety and efficient use of the power
tool.
Cause
The battery is discharged or defective.
The battery is not properly inserted.
The battery temperature is too high or too low.
The battery contacts are contaminated/dirty or defective. – Contact an authorised service agent for Bosch power tools.
The actuation system is blocked.
The magazine 12 is empty.
The discharge lock-off 2 is bent.
The electronic system is defective.
The following components may be faulty:
– Trigger 6
– Driver blade
– Motor or drive belt
– Electronic system
Foreign objects have accumulated in the shot mecha-
nism.
Foreign objects have accumulated in the outlet 15 or in
the magazine 12.
A nail is jammed in the shot duct.
The magazine slider is 13 defective.
The spring of the magazine slider is too week or defective. – Contact an authorised service agent for Bosch power tools.
The fasteners being used are not permitted.
manuals search engine
Action
– Blow out the mechanism of the magazine/magazine slider
daily with compressed air.
– Blow out the mechanism of the discharge lock-off daily with
compressed air.
Corrective Measure
– Fully recharge the battery or exchange it.
– Make sure that the battery has engaged properly in the han-
dle.
– Wait until battery has reached the optimal operating temper-
ature again.
Have the component replaced there.
– Press switch 5 toward the right to disengage the actuation
system.
– Refill the magazine.
(See "Loading the Magazine", page 12)
– Contact an authorised service agent for Bosch power tools.
Have the component replaced there.
– Contact an authorised service agent for Bosch power tools.
– Contact an authorised service agent for Bosch power tools.
Have the component replaced there.
– Contact an authorised service agent for Bosch power tools.
Have the component replaced there.
– Clean the outlet 15 or the magazine 12.
– Clear the jam.
(See "Clearing Jams", page 13)
– Clean the magazine slider 13 as required and make sure that
the magazine 12 is not dirty/soiled.
Have the component replaced there.
– Use only original accessories.
Only the fasteners (nails, staples, etc.) specified in table
"Technical Data" may be used.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis