4.2 User interface

1 2 3 4 5 6 7 8 9 10 11 1213 14
Fig. 13
Connection pins
Pin
Type
Description
1
4-20 mA
Vibration sensor
2
4-20 mA
Spare input
Supply output for 4-20 mA
3
13.5 VDC
sensors
4
4-20 mA
Water-in-oil/water-in-air sensor
5
GND
Common ground for sensors
6
P5
Communication signal for IO 113
7
PE
Protective earth
Supply input for sensor board
8
P4
from IO 113
9
N/A
-
10
Pt1000
Stator temperature
11
Speed
Reserved
Pt100/Pt1
12
Main bearing temperature
000
Pt100/Pt1
13
Support bearing temperature
000
Pt100/Pt1
14
Stator temperature
000
10

4.3 Identification

4.3.1 Type key
Code Meaning
SM
Sensor board
11
Controller series
3
Model number

4.3.2 Nameplate

The nameplate is fitted on the front of SM 113.
A
B
C
Type
Product No.
U
N
P
5W
MAX
N2042
Made in Thailand
I
H
Fig. 14
Nameplate
Pos.
Description
A
Type designation
B
Product number
C
Rated voltage
D
Version number
E
Serial number
F
Production code (year and week)
G
Enclosure class
H
EAC approval logo
I
Power consumption

4.4 Approval

SM 113 is UL listed to US and Canadian
safety standards.
SM
1
1
3
D
E
F G
V-No.
P.c.
Serial No.
IP
OPEN TYPE PROCESS
CONTROL EQUIPMENT
30 XP