5. Unplug the mains plug from the socket.
6. Secure mains plug against unintentional plug-in.
7. Switch off compressed-air supply.
8. Remove the compressed air hose from the EPS 200.
---Separator---
2.2

Removing the frequency inverter

DANGER
Contact with live parts in an opened frequency
inverter leads to electric shocks and heart
failure and may be fatal.
 Wait at least 15 minutes after switching off the
EPS 200 and before opening the cover over the
terminals. Do not open the cover over the
terminals until the waiting period of 15 minutes
has elapsed and the charge LED is off.
---Separator---
The description of the disassembly procedure
can be found in the servicing instructions for the
EPS 200 or EPS 205 in the section "Replacing the
frequency inverter".
1. On an EPS 200: Remove the protective hood.
On an EPS 200 with basic set 1 687 010 397:
Remove the protective cover.
2. Remove the safety switches.
3. Detach the housing sections.
4. Detach the jet chamber unit.
5. Detach the upper housing section.
6. Detach the LCD display assembly.
 DANGER - Contact with live parts in an opened
frequency inverter leads to electric shocks and heart
failure and may be fatal.
7. Open the cover over the terminals
frequency inverter after the charge LED
off. To open the cover over the terminals, first
release the electrical cabinet lock
 2:
Frequency inverter 1 687 023 433
8. Remove the RJ45 connecting cable.
9. Remove the internal cover over the terminals.
10. Disconnect the cables from the connections PE,
R/L1, S/L2 and T/L3.
1 689 978 635 | 2019-01-01
11. Before disconnecting the cables from connections
P0 and PA, ensure that the cables are identified (see
 3
— Identify the two cables as soon as they are
 3:
Connecting cables for line choke L1
12. Disconnect the cables from the connections P0 and
PA
13. Disconnect the cables from the connections U/T1,
V/T2, W/T3 and PE.
14. Remove the rear cover over the terminals.
15. Remove the grounding plate.
16. Remove 4 hex socket head cap screws and washers.
17. Remove the frequency inverter.
---Separator---
 2 (2)
of the
2.3
 2 (1)
is
 2 (3)
.
1. Carefully insert 4 spacers into the holes in the A1
control board and snap them in place
).
removed if the identification is no longer present
or cannot be read. This will prevent the cables
being inadvertently interchanged when
reattached.
Assembling and connecting circuit
board A2
On an EPS 200 with basic set 1 687 010 397,
circuit board A2 is already installed and
connected, and can be used to commission the
frequency inverter. In this case, you can skip this
section.
If bent excessively, control board A1 can be
damaged.
( 4
).
Robert Bosch GmbH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis