5
Maintenance and Cleaning
5.1
Maintenance
Ensure that the low profile scale is routinely calibrated, call
METTLER TOLEDO service.
5.2
Daily Checks
•
Check if the rocker feet are properly seated in the
blind hole of each load cell.
Check if the 4 feet are in contact with the floor.
•
•
Check if the scale is free from debris, especially
under the scale.
•
Check if there is no damage on the indicator con-
necting cable.
Check if the indicator power cable is not damaged.
•
5.3
Cleaning
Disconnect the power supply before cleaning
BUA221 painted carbon steel
•
Clean the scale with a soft cloth that has been
dampened with a mild soap.
BUA226 stainless steel, AISI304
•
Clean the scale with a soft cloth that has been
dampened with an appropriate cleaning solution for
stainless steel.
Do not use a steel or metal brush as this would lead
•
to surface corrosion.